4-1.

Serial Number And Rating Label Location

The serial number and rating information is located on the left side of the unit. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
4-2.

Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula
4-3.

Information About Default Weld Parameters And Settings

NOTICE – Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical
welding parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are
for reference purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriate-
ness of all parameters and settings should be evaluated and modified by the end user as necessary based upon application-specific require-
ments. The end user is solely responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld
parameters and settings, and ultimate quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warran-
ties including any implied warranty of fitness for a particular purpose.
4-4.

Specifications

The correction factor on the cooling power at an ambient temperature of 104°F (40°C) is 0.625.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Power Sources Rated Up To 280 Amperes.
Coolant Tank Capacity
Rated Cooling Power
Maximum Cooling Power
Input Voltage
Input Amperage
4-5.

Coolant Specifications

Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -37°F (-38°C) and resist algae growth.
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump,
radiator, etc.).
Complete Parts List is available at www.MillerWelds.com
SECTION 4 – SPECIFICATIONS
and are incorporated by reference herein.
1.3 gal (4.9 L)
1.33 kW at 1.06 qt/min at 77°F (4540 BTU/hr at 1.0 L/min at 25°C)
3.4 kW at 3.8 qt/min at 77°F (11,600 BTU/hr at 3.6 L/min at 25°C)
115 VAC, Single Phase, 50 or 60 Hz
5.9 Amperes, 60 Hz
4.7 Amperes, 50 Hz
Coolant
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 32°F (0°C)
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 32°F (0°C)
Aluminum Protecting Coolant 043809*
OM-257811 Page 7