Gmaw Connections - Miller Coolmate 1.3 Owner's Manual

Hide thumbs Also See for Coolmate 1.3:
Table of Contents

Advertisement

5-2.

GMAW Connections

3
1
11/16 in.
wrench
crescent wrench
Do not move or operate unit where it
could tip.
To prevent overheating, make sure cooling
unit is positioned so there is 12 in. (305 mm)
of unrestricted airflow on sides of unit.
NOTICE – If welding power source has a
water valve, do not connect hoses to water
valve. Connect hoses as shown.
nutdriver
1 Coolant Out Hose
chippinghammer
2 Coolant In Hose
wirecutter
frontcutter
Complete Parts List is available at www.MillerWelds.com
4
2
Fittings have 5/8-18 left-hand threads. Con-
nect hoses with proper fittings as shown.
Some power sources may require a TIG
block.
3 Coolant Tank Cap
4 115 Volt AC Grounded Receptacle
A dedicated circuit capable of carrying 15
amperes and protected by fuses or circuit
breakers is recommended. Recommended
fuse or circuit breaker size is 15 amperes.
Ref. 805501-A
Operation:
Fill tank with proper coolant. Use table in
Section 4-5 to select proper coolant. Main-
tain coolant level at approximately 1 in. (25
mm) below top of filler neck. Connect hoses
as shown. Unit turns on when plugged in.
OM-257811 Page 13

Advertisement

Table of Contents
loading

Table of Contents