Connections and Settings

Make sure to also consult the Power Board Unit Instruction Manual.
Power Supply Connection
G
N
L
For the connections use cables higher than
18 AWG.
<Live>
<Neutral>
<Ground>
• Fix the power cable end firmly so that the power
terminal connection does not come loose. Use
solderless terminals (ring or spade type) for wiring.
• After connection, always install the supplied power
terminal cover A for safety reasons.
Joint board
SIDE-A
All connection cables should be 24 AWG or higher with a
maximum length of no more than 600 m.
1
Controller connection
White
Yellow
485A
485B
2
Alarm signal input
IN 1 - 8
To COM
3
Alarm signal output
If a lamp is connected to this cable, it will light up
when an alarm signal is received or when the
built-in motion sensor detects movement.
OUT 1/2
To COM
For details on 2 and 3, refer to the "Alarm Settings (ALARM)" in
the Instruction Manual.
CAMERA
SET
LENS
SET
PAN/TILT
SET
AUTO MODE
SET
ALARM
SET
PRIVACY MASK
SET
PASSWORD
SET
LANGUAGE
SET
OPTION
SET
PRESET
OFF
MENU
BACK
AC 24 V
or
AC 230 V
Connections
Alarm input
signal
Alarm output
signal
ALARM
ALARM IN
1
y
ALARM OUT
1
y
ALARM DISABLE
OFF
MOTION
OFF
ALARM DISPLAY
OFF
PRESET
OFF
MENU
BACK
Cable type
RG-59U (3C-2V)
RG-6U (5C-2V)
RG-11U (7C-2V)
• Using different cables from those specified here may attenuate the
A
video and/or sync signals and interfere with correct transmission.
• RG-59U coaxial cables can be used when distance between
devices is short, but not in duct or aerial routing.
BNC type
2
1
System control setting switches
• Switch 6 is unused.
• The factory setting is represented in bold.
1
Baud rate
Set the same baud rate as that on the camera.
Switch
2400
4800
9600
19200
2
Control method
Set either to RS485 or coaxial (COAX).
Switch
Coaxial (COAX)
RS485
3
Protocol
Set the protocol for controlling the camera.
Switch
SSP (SANYO)
PELCO
4
Termination (Switch 5)
"OFF" is set by default.
When connecting multiple cameras, termination setting must be "ON"
on the last camera while it must be "OFF" on all others.
2
Address setting switches
Set the camera address.
See "Address Settings Table" on page 7.
– 5 –
Do not connect the power cord until all other
connections have been completed.
Monitor Connection
Supported coaxial cables
Length
250 m (273.4 yd) max.
500 m (546.8 yd) max.
600 m (656.2 yd) max.
1
Switch Settings
SIDE-B
1
2
OFF OFF
OFF ON
ON OFF
ON
ON
3
ON
OFF
4
OFF
ON
ON
1
2
3
4
5
6
1 234
ON
1
2
3
4
5
6
7
8