Installing/Mounting
2.2 Mounting the Transmitter
Pipe Mounting
For installation on 2-inch (6 cm) mounting pipe use Pipe Mount Kit CQO:1012NMB-1
(optional - see catalog). See figure below.
Note
Pipe mounting kit CQO:1012NMB-1 is not available for IP66 NEMA 7 enclosures.
Figure 2-1
Note
Use conduit fittings or cable glands on all cables.
16
2-in (6cm) pipe
Transmitter
Mounting Plate
Pipe Mounting and Mounting Locations for Transmitter
Cable Entry Ports
Mounting Flange (also use for wall mounting)
U-Bolt Assembly for standard 2-in (6 cm) mounting pipe
FUS1010 IP65 NEMA 4X & IP66 NEMA 7 Quick Start
Operating Instructions, 01/2013, A5E03086486-AC