the anchor device or anchor point for the fall arrest system should always be positioned, and the work carried out in such a way, as to
·
minimise both the potential for falls and potential fall distance. The anchor device/point should be placed above the position of the
user . The shape and construction of the anchor device/point shall not allowed to self-acting disconnection of the equipment.
Minimal static strength of the anchor device/point is 12 kN. It is recommended to use certified and marked structural anchor point
complied with EN795
it is obligatory to verify the free space required beneath the user at the workplace before each occasion of use the fall arrest system,
·
so that, in the case of a fall, there will be no collision with the ground or other obstacle in the fall path. The required value of the free
space should be taken from instruction manual of used equipment.
there are many hazards that may affect the performance of the equipment and corresponding safety precautions that have to be
·
observed during equipment utilization, especially: - trailing or looping of lanyards or lifelines over sharp edges, - any defects like
cutting, abrasion, corrosion, - climatic exposure, - pendulum falls, - extremes of temperature, - chemical reagents, - electrical
conductivity.
personal protective equipment must be transported in the package (e.g.: bag made of moisture-proof textile or foil bag or cases
·
made of steel or plastic) to protect it against damage or moisture.
the equipment can be cleaned without causing adverse effect on the materials in the manufacture of the equipment. For textile
·
products use mild detergents for delicate fabrics, wash by hand or in a machine and rinse in water. Plastic parts can be cleaned only
with water. When the equipment becomes wet, either from being in use or when due cleaning, it shall be allowed to dry naturally, and
shall be kept away from direct heat. In metallic products some mechanic parts (spring, pin, hinge, etc.) can be regularly slightly
lubricated to ensure better operation. Other maintenance and cleaning procedures should be adhered to detailed instructions stated
in the manual of the equipment.
personal protective equipment should be stored loosely packed, in a well-ventilated place, protected from direct light, ultraviolet
·
degradation, damp environment, sharp edges, extreme temperatures and corrosive or aggressive substances.
IT IS THE RESPONSIBILITY OF THE USER ORGANISATION TO PROVIDE THE IDENTITY CARD AND TO FILL IN THE DETAILS REQUIRED. THE
IDENTITY CARD SHOULD BE FILLED IN BEFORE THE FIRST USE BY A COMPETENT PERSON, RESPONSIBLE INTHE USER ORGANIZATION FOR
PROTECTIVE EQUIPMENT. ANY INFORMATION
ABOUT THE EQUIPMENT LIKE PERIODIC INSPECTIONS, REPAIRS, REASONS OF
EQUIPMENT'S WITHDRAWN FROM USE SHALL BE NOTED INTO THE IDENTITY CARD BY A COMPETENT PERSON. THE IDENTITY CARD
SHOULD BE STORAGED DURING A WHOLE PERIOD OF EQUIPMENT UTILIZATION. DO NOT USE THE EQUIPMENT WITHOUT THE IDENTITY
CARD. ALL RECORDS IN THE IDENTITY CARD CAN BE FILLED IN ONLY BY A COMPETENT PERSON.
IDENTITY CARD
MODEL AND TYPE OF EQUIPMENT
SERIAL NUMBER
USER NAME
DATE OF PURCHASE
PERIODIC EXAMINATION AND REPAIR HISTORY
REASON FOR
DATE
ENTRY PERIODIC EXAMINATION
OR REPAIR
AND OTHER REVELANT INFORMATIONS
1
2
3
4
5
6
PROTEKT, 93-403 LODZ,
ul. Starorudzka 9, POLAND,
TEL: (48 42) 680 20 83, FAX: (48 42) 680 20 93
www.protekt.com.pl
REF. NUMBER
DATE OF MANUF.
DATE OF PUTTING
INTO OPERATION
DEFECTS NOTED,
NAME AND SIGNATURE
REPAIRS CARRIED OUT
OF COMPETENT PERSON
Notified body, at which the European certification
was performed and which supervises
the production of the equipment:
APAVE SUDEUROPE SAS - CS 60193 - 13322 MARSEILLE CEDEX 16 - FRANCE
Instruction Manual
READ CAREFULLY BEFORE USE
THE EQUIPMENT
Safety harness is the basic element of fall arrest equipment. The harness P-16 complies with EN 361 (as a full body
harness) and EN 813 (as a sit harness) - the maximum load of the sit harness is 140 kg. The harness is made of
polyester webbings.
shoulder straps
crossing plate
chest strap connecting/
adjustment buckle
shoulder strap
adjustment buckles
frontal sit harness D-
rings EN 813. It's not
allowed to use sit
harness D-RINGS with
fall arrest systems
leg strap
connecting/
adjustment
buckles
Periodic inspections
The safety harness P-16 must be inspected at least once every
12 months from the date of first use.
PERIODIC
Periodic inspections must only be carried out by a competent
EXAMINATION
NEXT DUE DATE
person who has the knowledge and training required for
personal protective equipment periodic inspections. Depending
upon the type and environment of work, inspections may be
needed to be carried out more frequently than once every 12
months. Every periodic inspection must be recorded in the
Identity Card of the equipment.
Maximum lifespan of the equipment
The maximum lifespan of the harness P-16 is 10 years from the
date of manufacture.
The harness
must be withdrawn from use immediately and
destroyed when it has been used to arrest a fall or
pass inspection or there are any doubt as to its reliability.
ATTENTION: The harness maximum lifetime depends on the
intensity of usage and the environment of usage. Using
theharness in rough environment, marine environment, contact
with sharp edges, exposure to extreme temperatures or
agressive substances, etc. can lead to the wthdrawal from use
even after one use.
SAFETY
EN 361:2002
HARNESS
Ref. AB 1
16
01
EN 813:2008
HARNESS MARKING
P-16
a
b
SAFETY HARNESS
c
d
Size:
e
Date
of manufacture:
f
Serial number:
it fails to
g
h
i
j
k
P-16
back attachment
D-ring
webbing
keeper
identity label
(harness
marking)
sit harness pad
back strap
adjustment
buckle
leg straps
a)
Model symbol
;
b) Device type;
c) Reference number;
d) Harness size;
e) Month and year of
manufacture;
f) Serial number of the
Ref. AB 116 01
harness;
XXL
M-XL
g) Number/year European
standards;
h) CE mark and number of
MM/YYYY
the notified body
controlling manufacturing
XXX XXX
of the equipment;
EN 361:2002
i) Caution: read and
EN 813:2008
understand the
instruction manual before
use;
j) Max. weight for the sit
harness use;
k) Identification of the
harness manufacturer or
distributor.
Need help?
Do you have a question about the P-16 and is the answer not in the manual?
Questions and answers