C. Using a C-1000B without a C.O. Line
The C-1000B can also be used without a C.O. line. This is ideal for
connecting the C-1000B to an unused trunk/line input of your phone
system or connecting to phones used only for doorbox communication.
Step 1. Connect the power, required doorboxes, and doorstrike outputs
(if required) as shown in section A.
Step 2. Connect an analog phone or PABX/KSU trunk port to terminals
4 & 5, "LINE OUT TO PHONES" output on the C-1000B.
Step 3. Be sure the "Talk Battery Switch" is in the ON position.
D. Using the C-1000B with Keyless Entry, Proximity Card Reader or a Postal Lock Switch
Step 1. Connect a device that can provide a
momentary contact closure, such as
the Viking ES-1 with HID-1 Card
Reader or HID-2 Keypad, keyed
switch, postal lock with limit switch,
etc. to terminals 6 & 7, "KEYLESS
CONTACT CLOSURE INPUT".
Step 2. Connect doorboxes and doorstrike
outputs (if required) as shown in
section A.
Step 3. See Operation section A, 5. Keyless
Entry/Postal Lock.
Need More Information on the ES-1?
?
Call (715) 386-4345 and select 193.
Need More Information on the HID-2?
?
Call (715) 386-4345 and select 199.
E. Using the C-1000B to Trigger a Doorbell
Step 1. Connect the doorbell (not included) as shown to the right.
Note: The C-1000B will not supply power to the doorbell,
a power adapter is necessary.
Step 2. Connect doorboxes and doorstrike outputs (if required)
as shown in section A.
Step 3. Program the Auxiliary Contact Output as desired (see
Programming section B).
Step 4. See Operation section A, 6. Auxiliary Contacts.
F. Line Concentrator Mode
The C-1000B can be used as a line con-
centrator, allowing up to 3 separate C.O.
lines to connect to one telcom device.
Step 1. Connect as shown to the right.
Step 2. Move DIP switch 3 to the OFF posi-
tion (see Programming section E).
Step 3. Be sure the "Talk Battery Switch"
is set to OFF.
Step 4. See Operation section C.
(4)
VIKING
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
COM
SIG GND
SIG GND
VIDEO 1 IN
VIDEO 2 IN
EARTH
C.O. LINE
OUT TO
GND
INPUT
PHONES
(One Telcom Device Can Answer up to Three Lines)
13.8V AC
Adapter
included
Earth Ground
(see page 2)
C.O. Line
or Analog
PABX/KSU
station
Fax Machine
VIKING
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
SIG GND
VIDEO 1 IN
EARTH
C.O. LINE
GND
MODEL C-1000B
©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
/ PAGING CONTROLLER
N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
ON
SIG GND
VIDEO OUT
1
2
3
C
C
C
TALK
BATTERY
LED1
LED2
LED3
OFF
ON
KEYLESS
DOOR
DOORBOX
DOOR
N.O. COM N.C.
N.O. COM N.C.
C.C. INPUT
BOX 1
13VAC PWR
BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
and/or
Keyed Momentary Switch/
Postal Lock with Limit
Switch (not included)
Need More Information on the HID-1?
?
Call (715) 386-4345 and select 197.
120V AC
VIKING
DOOR ENTRY / CCTV VIDEO
/ PAGING CONTROLLER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
COM
N.O. N.C. - - - - AUX.
SIG GND
SIG GND
SIG GND
VIDEO 1 IN
VIDEO 2 IN
VIDEO OUT
LED1
Line 1
EARTH
C.O. LINE
OUT TO
KEYLESS
GND
INPUT
PHONES
C.C. INPUT
or
Answering
Standard
Machine
Analog Phone
MODEL C-1000B
©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
/ PAGING CONTROLLER
COM
N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
ON
SIG GND
SIG GND
VIDEO 2 IN
VIDEO OUT
C
C
1
2
3
C
TALK
BATTERY
LED1
LED2
LED3
OFF
ON
OUT TO
KEYLESS
DOOR
DOORBOX
DOOR
N.O. COM N.C.
N.O. COM N.C.
INPUT
PHONES
C.C. INPUT
BOX 1
13VAC PWR
BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
VIKING
MODEL ES-1
©
VIKING
ELECTRONICS
HUDSON, WI 54016
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
ENTRY POINT
WIEGAND
DEVICE
GANG
LOG
PROG
BUS
COMM
PROGRAM
PHONE
Viking HID-1
Proximity Card
Reader (not included)
VIKING
MODEL C-1000B
©
VIKING
ELECTRONICS
HUDSON, WI 54016
DOOR ENTRY / CCTV VIDEO
/ PAGING CONTROLLER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
COM
N.O. N.C. - - - - AUX.
CONTACT
OUTPUT
ON
SIG GND
SIG GND
SIG GND
VIDEO 1 IN
VIDEO 2 IN
VIDEO OUT
1
2
3
C
C
TALK
BATTERY
LED1
LED2
OFF
ON
EARTH
C.O. LINE
OUT TO
KEYLESS
DOOR
DOORBOX
DOOR
N.O. COM N.C.
N.O. COM N.C.
GND
INPUT
PHONES
C.C. INPUT
BOX 1
13VAC PWR
BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
Not to Exeed: .5A @ 125V AC
or 1A @ 30V AC
MODEL C-1000B
©
Talk Battery Switch
VIKING
ELECTRONICS
HUDSON, WI 54016
OFF
ON
CONTACT
OUTPUT
ON
OFF
1
2
3
C
C
C
TALK
BATTERY
LED2
LED3
OFF
ON
DOOR
DOORBOX
DOOR
N.O. COM N.C.
N.O. COM N.C.
BOX 1
13VAC PWR
BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
Line 3
Red
Green
Line 2
Red
Green
Talk Battery
Switch
OFF
ON
Viking HID-2
Keypad
(not included)
and/or
C
LED3
Doorbell
(not included)
ON
ON
1
2
3
C.O. Line
or Analog
PABX/KSU
station
C.O. Line
or Analog
PABX/KSU
station

Advertisement

Table of Contents
loading

Table of Contents