FIGURE 2 - Standard Wall Mounting
If the wall mounting plate must be mounted higher than 4" above
the door opening, it must be spaced out from the wall
every additional inch (over 4") that the unit is above the door
opening. See Figure 3
For optimum protection, do not exceed the recommended maxi-
mum mounting height of 8' above the finished floor. Any void
between the mounting plate and the wall should be sealed along
the full length of the mounting plate.
E. Determine which of the four holes provided in each of the steel
brackets of the wall mounting plate are located where suitable
support is available for the unit. Minimum one inside hole and
one outside hole from each bracket must be used for proper
support. Drill out the aluminum backing of the holes chosen with
a ¼" drill bit. If the provided holes on the mounting plate are not
located where suitable support is available, drill new holes in the
space provided on the steel mounting brackets.
F. Mark the wall in the centers of the ¼" holes drilled on the mount-
ing plate.
G. Attach the mounting plate to the wall (hardware by others).
H. The top of the unit is provided with two knockouts on each side
allowing for a left or right hand power connection. Remove the
wiring tray cover; on units that are comprised of modules, re-
move the wiring tray cover that is located closest to the electrical
FIGURE 3 - High Wall Mounting
rating nameplate. Remove the required knockouts and attach
necessary electrical hardware. Save the wiring diagram found
inside of wiring tray. See Figure 7
I. There are two sets of keyhole slots on the wall mounting plate.
In low overhead installations the air door may be staged in the
lower keyholes to provide clearance for electrical wiring and
then moved to the higher holes after completion. Raise the air
door with the discharge opening facing down toward the floor.
While holding the unit level, slide the heads of the shoulder
bolts into the larger hole of the keyhole slots of the mounting
plate. Lower the unit into place, keeping both ends level, allow-
ing it to rest flush with the mounting plate. See Figure 4
J. After attaching the unit to the mounting plate, ensure that the
unit is seated and flush with the mounting plate on all four sides.
K. Proceed to Section V - Electrical Connections.
/
3
" for
8
FIGURE 4 - Installing Air Door on Wall Mounting Plate
IV.

SUSPENDED MOUNTING

(Ceiling Suspension)
A. When the unit is top mounted, the wall mounting plate is de-
signed to store on the back of unit for future use. See Figure 5
FIGURE 5 - Wall Mounting Plate Storage