Installation & Maintenance Instructions

TABLE OF CONTENTS

I. UNCRATING............................................................................................................................................................ ........................................................ 2
II. GENERAL MOUNTING INSTRUCTIONS ................................................................................................................................. ................................... 4
III. WALL MOUNTING ...................................................................................................................................................................................................... 5
IV. SUSPENDED MOUNTING ....................................................................................................................................... ................................................... 5
V. ELECTRICAL CONNECTIONS ..................................................................................................................................................................................... 6
VI. FIELD CONNECTIONS ................................................................................................................................................................................................ 6
VII. OPERATING INSTRUCTIONS .................................................................................................................................................................................... 7
INTELLISWITCH™
QUICK START OPERATION ................................................................................................................................................................................... 10
FAQ's (FREQUENTLY ASKED QUESTIONS) ......................................................................................................................................................... 12
VIII. MAINTENANCE AND CLEANING ............................................................................................................................................................................ 8
IX. SERVICE ............................................................................................................................................................... ........................................................ 8
X. TROUBLESHOOTING ................................................................................................................................................................................................. 14
A. SERIAL NETWORK CONNECTION (PREVIOUSLY MASTER / SLAVE CONNECTION) ................................................................................ 15
B. WALL MOUNTED TOUCHSCREEN ................................................................................................................................................ .................. 15
XII.WARRANTY ................................................................................................................................................ ............................................................... 16
Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years.
Berner offers unmatched quality, performance, and dependability-not to mention our service. At Berner, we stand behind our products.
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN
IMPORTANT INSTRUCTIONS
®
save energy & create healthy, comfortable environments
Thank you for choosing Berner.
Architectural Elite 8 & 10
Air Curtain Series
#AE08 & AE10
©Copyright, 2020 Berner International
II-260D
May, 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AE08 and is the answer not in the manual?

Questions and answers

Summary of Contents for Berner AE08

  • Page 1: Table Of Contents

    Thank you for choosing Berner. Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years. Berner offers unmatched quality, performance, and dependability—not to mention our service. At Berner, we stand behind our products.
  • Page 2: Uncrating

    Contact Berner, if they are required, for no charge. Immediately verify that the electrical rating nameplate located on the cover matches the electrical power supply available.
  • Page 3 CATCH WALL HANGERS* (Position evenly; slide to match location of support structure) 1/4”-20 BOLTS provided by Berner (4 FT-LBS RECOMMENDED TORQUE) *Longer units use more than two wall hangers. After mounting the wall hangers, hang the air curtain and Position outer wall hangers no more than 6” from the end.
  • Page 4: General Mounting Instructions

    Net Weight inlet screen, and to ensure proper airflow. AE10 MODEL MODEL AE10 AE10 AE08 AE08 AE08 Hot When determining the mounting location for the air Ambient Electric Ambient Electric Water Water curtain(s), make sure that nothing interferes with the...
  • Page 5: Wall Mounting

    See Figure 4. For units over 72", there are more than two wall hangers. Use ¼"-20 bolts, provided by Berner, to attach the CATCH mounting catch and hook to the back of the air curtain.
  • Page 6: Electrical Connections

    V. ELECTRICAL CONNECTIONS KNOCKOUTS FOR POWER & CONTROL All electrical wiring and connections MUST be performed by WIRING qualified personnel in accordance with the latest edition of the National Electrical Code ANSI/NFPA No. 70 or, in Canada, the WIRING Canadian Electrical Code, Part 1-C.S.A. Standard C22.1 and local COMPARTMENT codes and regulations.
  • Page 7: Operating Instructions

    Intelliswitch™ thermostat located on top of the air curtain. Piping should be done in accordance with local codes, regulations and standard practices. Connect the building system to the (3/4"-AE08 or 1"- AE10) MPT supply and return header connections. See Figure 8. Figure 8 - Hot Water Connections VII.
  • Page 8: Maintenance And Cleaning

    Any service performed on the ARCHITECTURAL ELITE Series air curtain MUST be done by qualified personnel. Berner air curtains require very little servicing. All parts are easily accessible for periodic inspection and maintenance. Units should be cleaned at least twice a year.
  • Page 9 CAUTION: ELECTRIC SHOCK HAZARD Disconnect power whenever servicing unit. More than one disconnect may be required to de-energize unit. AE08: To replace fans and/or motors Lock out power to the unit. Remove the bottom access cover by removing the Phillips head screws across the top front of the unit.
  • Page 10: Quick Start Operation

    QUICK START INSTRUCTIONS For your Berner Air Curtain with Intelliswitch™ Gen4 www.Berner.com/intelliswitch NOTE – to navigate, use to select setting to change setting, then press to enter the setting. Stop: Immediately stops the air curtain and changes mode to OFF "i": info button provides controller status and diagnostic data...
  • Page 11 Customizable Mode of Operation Options: www.berner.com/intelliswitch for programming directions (Section 5, Program Menu). STEP THREE Once the Mode of Operation is selected, press the button. Berner International www.berner.com 800.245.4455 111 Progress Ave. / New Castle / PA / 16101 / USA -11-...
  • Page 12: Faq's (Frequently Asked Questions)

    INTELLISWITCH™ Gen4 FAQ’s (Frequently Asked Questions) www.Berner.com/intelliswitch WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
  • Page 13 INTELLISWITCH™ FAQ’s Continued (Frequently Asked Questions) www.Berner.com/intelliswitch 4. If the air curtain is heated, make sure that the thermostat Q. Why didn’t the Intelliswitch™ save the changes I made to isn’t wired to the door switch leads. Door switch leads a program? are blue and labeled 9 &...
  • Page 14: Troubleshooting

    X. TROUBLESHOOTING SYMPTOMS CAUSE REMEDY • Power supply line open (no power) • Check power source, check service disconnect, NO AIR check method of control in ON position • Fuse blown/circuit breaker tripped • Replace fuse(s)/reset breaker • Motor overload tripped • Internally protected motor - should reset automatically after cool-down, if not, replace motor. • Failed switch • Replace switch MOTOR RUNNING/FANS ARE NOT ROTATING • Broken or damaged flexible hub • Replace fan sleeve/reengage coupling • Tighten set screws/tighten fan on shaft • Shaft rotating inside fan ELECTRICAL CONTROLS NOT FUNCTIONING WHEN DOOR IS OPEN • Selector switch is in off position • Turn switch to “ON” position • Door limit switch not operating...
  • Page 15: Appendix

    All program settings are included in the installation instructions shipped with the air curtain. 5. Models AE08-E and AE10-E air curtains include a wireless controller that works with the Berner App. When connected to the local Wi-Fi network, they can be programmed from a smart phone using the Berner AIR™...
  • Page 16: Xii.warranty

    XII. WARRANTY Berner International ("The Company") warrants all new equipment to be free of defects in workmanship and material for a period of five years (5 years) on unheated models and two years (2 years) on heated models from the original date of shipment, provided the equipment has been properly cared for, installed and operated in accordance with the limits specified on the nameplate and The Company’s instructions.