TABLE OF CONTENTS

I. UNCRATING............................................................................................................................................................ ........................................................ 2
II. GENERAL MOUNTING INSTRUCTIONS ................................................................................................................................. ................................... 4
III. WALL MOUNTING ...................................................................................................................................................................................................... 5
IV. SUSPENDED MOUNTING ....................................................................................................................................... ................................................... 5
V. ELECTRICAL CONNECTIONS ..................................................................................................................................................................................... 6
VI. FIELD CONNECTIONS ................................................................................................................................................................................................ 6
VII. OPERATING INSTRUCTIONS .................................................................................................................................................................................... 7
INTELLISWITCH™
QUICK START OPERATION ..................................................................................................................................................................................... 9
FAQ's (FREQUENTLY ASKED QUESTIONS) ......................................................................................................................................................... 11
VIII. MAINTENANCE AND CLEANING ............................................................................................................................................................................ 8
IX. SERVICE ............................................................................................................................................................... ........................................................ 8
X. TROUBLESHOOTING ................................................................................................................................................................................................. 13
A. SERIAL NETWORK CONNECTION (PREVIOUSLY MASTER / SLAVE CONNECTION) ................................................................................ 14
B. REMOTE MOUNTED DISPLAY FACEPLATE ................................................................................................................................................ .... 14
C. INFRA-RED REMOTE CONTROL ................................................................................................................................................ ...................... 14
D. PUREAIR PACKAGE ........................................................................................................................................................................................... 15
XII.WARRANTY ................................................................................................................................................ ............................................................... 16
Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years.
Berner offers unmatched quality, performance, and dependability-not to mention our service. At Berner, we stand behind our products.
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN
indoor use
Thank you for choosing Berner.
Architectural
High Performance 10
Air Curtain Series #AHD10
©Copyright, 2020 Berner International
II-260D
May, 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Architectural High Performance 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Berner Architectural High Performance 10

  • Page 1: Table Of Contents

    Thank you for choosing Berner. Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years. Berner offers unmatched quality, performance, and dependability—not to mention our service. At Berner, we stand behind our products.
  • Page 2: Uncrating

    Architectural High Performance 10 Air Curtain (Air Door) WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Read all instructions before installing or using this air curtain. B. Use this unit only in the manner intended by the manufacturer and described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
  • Page 3 Side View The controls ship in the same box as the air curtain. For more information see page 5 For more information see page 6 Berner International www.berner.com 800.245.4455 111 Progress Ave. / New Castle / PA / 16101 / USA...
  • Page 4: General Mounting Instructions

    4" minimum INDOOR MOUNTING ONLY - 8" minimum* side The Architectural High Performance 10 Air Curtain is designed clearance to be an effective barrier against cold drafts in the winter from and hot air in the summer, flying insects and airborne...
  • Page 5: Wall Mounting

    III. WALL MOUNTING 45º Lip and Rubber Recommended Mounting Vibration Gasket Plate Holes PREPARATION Position and center the mounting plate over the door opening. The mounting plate must be positioned with the 45° lip and the rubber vibration gasket on top. Mark and drill holes on the mounting plate where the wall will provide sufficient support for the Doorway Opening...
  • Page 6: Electrical Connections

    V. ELECTRICAL CONNECTIONS Junction Box All electrical wiring and connections MUST be performed by qualified personnel in accordance with the latest edition of the National Electrical Code ANSI/NFPA No. 70 or, in Canada, the Canadian Electrical Code, Part 1-C.S.A. Standard C22.1 and local codes and regulations.
  • Page 7: Operating Instructions

    FIGURE 8 - Steam/Hot Water Connections VII. OPERATING INSTRUCTIONS A. GENERAL OPERATION This air curtain comes with a built-in Berner Intelliswitch™ Digital Controller to operate the fan activation, fan speed selection, and heat activation. The air curtain must be properly installed before it is used.
  • Page 8: Maintenance And Cleaning

    Any service performed on the ARCHITECTURAL HIGH PERFORMANCE 10 Series air curtain MUST be done by qualified personnel. Berner air curtains require very little servicing. All parts are easily accessible for periodic inspection and maintenance. Units should be cleaned at least twice a year.
  • Page 9: Quick Start Operation

    QUICK START INSTRUCTIONS For your Berner Air Curtain with Intelliswitch™ www.Berner.com/intelliswitch NOTE – to navigate use up/down to select setting and left/right to change setting Mode/Fan Speed: Mode: Select your mode of operation (see steps on page 2) Fan Speed: Sets the speed of the fan...
  • Page 10 3 Customizable Mode of Operation Options: www.berner.com/intelliswitch for programming directions (Section 5, Program Menu). STEP THREE Once the Mode of Operation is selected, press the“OK” button Berner International www.berner.com 800.245.4455 111 Progress Ave. / New Castle / PA / 16101 / USA -10-...
  • Page 11: Faq's (Frequently Asked Questions)

    Even though every Architectural High Performance 10 is individually tested at the factory before shipment, on occasion improper functionality may be experienced. Here is a list of common questions: Q.
  • Page 12 INTELLISWITCH™ FAQ’s Continued (Frequently Asked Questions) www.Berner.com/intelliswitch heat should shut off when the wires are separated. any mode that is activated by the door switch. For more complex troubleshooting of either thermal cutouts or 5.) If the air curtain is heated, make sure that the thermostat heater contactors, please consult a qualified electrician or the isn’t wired to the door switch leads.
  • Page 13: Troubleshooting

    X. TROUBLESHOOTING CAUSE SYMPTOMS REMEDY • Power supply line open (no power) • Check power source, check method of control in ON NO AIR position • Fuse blown/circuit breaker tripped • Replace fuse(s)/reset breaker • Motor overload tripped • Internally protected motor - should reset automatically after cool-down, if not, replace motor.
  • Page 14: Appendix

    Intelliswitch™ air curtain when connected to the local WiFi network they can display (including multiple button presses) with one exception, be programmed from a smart phone using the Berner the Lock Button. app.
  • Page 15: Pureair Package

    D. PureAir Package™ Air purification system for Berner air curtains. All air curtains equipped with the PureAir Package include EC motors and the “PURE” setting in the menu settings of the Intel- liswitch. The unit(s) are shipped with the PURE mode already selected.
  • Page 16: Xii.warranty

    XII. WARRANTY Berner International ("The Company") warrants all new equipment to be free of defects in workmanship and material for a period of five years (5 years) on unheated models and two years (2 years) on heated models from the original date of shipment, provided the equipment has been properly cared for, installed and operated in accordance with the limits specified on the nameplate and The Company’s instructions.

This manual is also suitable for:

Ahd10

Table of Contents