Download Print this page
hager RE 410 Series Quick Start Manual
hager RE 410 Series Quick Start Manual

hager RE 410 Series Quick Start Manual

Audio module built-in 2 wire, audio insert replacement built-in 2 wire

Advertisement

Quick Links

RE..410..
AUDIO module built-in 2 wire
RE..310..
AUDIO insert replacement built-in
2 wire
Safety instructions
Electrical equipment may only be installed
and assembled by a qualified electrician in
accordance with the relevant installation
standards, guidelines, regulations, directives,
safety and accident prevention regulations of
the country.
When installing and laying cables, always
comply with the applicable regulations and
standards for SELV electrical circuits.
These instructions are an integral component
of the product and must be retained by the
end user.
Design and layout of the device
(1)
(2)
(3)
Figure 1: Design and layout audio module device
front
1
(1)
z
(2)
(3)
Figure 2: Design and layout audio module with
module carrier device front
(1)
(2)
(3)
Figure 3: Design and layout audio insert device front
(1) Microphone
(2) Speaker
(3) Twilight sensor
(4) Cover plates stainless steel
(5) Module carrier (according to reference)
(6)
(7)
(8)
(9)
(10)
Figure 4: Design and layout audio modules and
audio-insert back-side
(6) Adjustment button Upwards
(7) 7-segment display
(8) Selection button
(9) Adjustment button downwards
(10) Module bus connector
(11) Connection terminal block
Function
The device works in the 2-wire bus system and
enables communication via sound.
(4)
Correct use
- for surface-mounted, flush-mounted or built-in
installation
- Not compatible with intercom systems of other
manufacturers
- suitable for use exterior applications
Product characteristics
- One-man commissioning
(5)
- expandable for modules, e.g. call push-button
- Call push-button acknowledge tone (can be
switched off)
- call button, light release or door release can be
adjusted even without any function
- Switch-on brightness level of the call button
backlighting adjustable
- Loudspeaker and microphone protected against
(4)
sabotage
- Volume and microphone sensitivity settable
- Door release contact on 1 ... 10 s adjustable
- Door release without previous call adjustable in
single door systems
Operation of call push-buttons
Call push-button modules are connected to the device.
Establish call (ringing)
z Press the call push-button assigned to the
desired subscriber.
If configured, the call push-button activation is
confirmed by an acknowledge tone. Addressed
indoor stations are called.
Switch-on lights
A call push-button is configured and labelled for
lighting control.
z Press the call push-button for lighting.
If configured, the call push-button activation is
confirmed by an acknowledge tone. The light
contact of a line power supply is closed for the
set time.
Label call push-button
z Keep call push-button pressed on one side.
On the opposite side, the lever opening (12) is
accessible for a screwdriver.
z Position the screwdriver in the lever opening
(12) and release the interlock (Figure 5).
z Remove cover with name plate insert.
(11)
Figure 5: Name plate change
(12) Lever opening
z Label name plate insert if required.
z Insert name plate insert, prepared foil or
prepared labelling strip into the cover.
z Press on cover.
Do not use any paper for the name plate insert,
P
since moisture and UV light will damage the
paper and labelling.
UV-resistant foil with laser printing is suitable
P
for labelling as well as labelling devices for
labelling strip:
- small buttons - 12 mm
- medium buttons - 30 mm
Detailed labelling references are to be found on
our homepage.
(12)
6LE002642A Ind. A

Advertisement

loading

Summary of Contents for hager RE 410 Series

  • Page 1 Product characteristics - One-man commissioning - expandable for modules, e.g. call push-button - Call push-button acknowledge tone (can be switched off) - call button, light release or door release can be adjusted even without any function - Switch-on brightness level of the call button backlighting adjustable - Loudspeaker and microphone protected against sabotage...
  • Page 2 Door stations with status indication Connect device The connection cables and indoor stations are Dis- Cause Function/Lighting duration connected to the line power supply while taking play the maximum cable lengths and attenuations into A subscriber After 90 s without call ac- account (see operating instructions of the line power is called.
  • Page 3 Calling up and navigating system settings = Call push-button address Address/Function Confirm the call On the back of the device, there are 3 buttons and = Light push-button Individual call push- saved, push-button to be set a 2-digit 7-segment display (Figure 4, 6-9) for the = Door release push-button button address/function is displayed...
  • Page 4 Appendix z Confirm set address/function with The device applies the setting and returns to Technical data the previous menu entry. Operating voltage 22 ... 24 V= Display saved error codes Current consumption audio Stand by 5 mA Device errors of the call push-button module that Current consumption audio device operation 110 mA occur during operation are stored in the the error...

This manual is also suitable for:

Re 310 series