Replacing The Lcd - Fluke 187 Calibration Manual

True rms multimeter
Hide thumbs Also See for 187:
Table of Contents

Advertisement

187/189
Calibration Manual

Replacing the LCD

If you need to replace the LCD, you will find it easier to leave the LCD assembly
attached to the circuit board and access the LCD by removing the LCD mask from the
front of the LCD assembly.
1. Remove the circuit board as described under "Removing and Reinserting the Circuit
2. Carefully insert the tip of a thin screwdriver under the LCD mask at the top of the
3. Lift up the LCD mask gently with the screwdriver blade to loosen the mask from the
4. Replace the LCD. The LCD must be centered on the platform between the brackets
5. Reattach the LCD mask by pressing it over the LCD until it snaps into place.
12
Board Assembly."
display as shown in Figure 1.
Figure 1. Removing LCD Mask to Access LCD
assembly. Be careful to press upward, not inward toward the LCD. By hand, tilt the
LCD mask upward to release.
before you replace the LCD mask. If the LCD is improperly aligned, the display may
show missing segments or meaningless readings.
LCD Mask
LCD
aau05f.eps

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

189

Table of Contents