LAUNCH

Standard Waveforms

This function is for conveniently analyzing various
automotive sensors. It provides the user with multiple
choice of voltage / time DIV and the characteristics of
standard output waveforms for various sensors and
actuators.
When [2.STANDARD WAVEFORM] is selected on
the main help menu, a dialogue box will appear as
shown in Fig.2-14, which lists the name of sensors or
actuators.
Select one of the sensors/actuators (totally 16). Its
waveform will appear on the right of the screen. For
example, if [3. O
SENSOR] is selected, its standard
2
output waveform and proper voltage / time DIV will be
displayed on the right of the screen as shown in
Fig.2-15.

Standard Erase

If it is not necessary to see the reference waveform,
user can press [HELP] key to return to the main help
Fig.2-14
Fig.2-15
KES-200
menu and choose [3.STANDARD ERASE] from the
menu to display the output waveform from the
oscilloscope.

Help Information On Sensors

The help information on sensors describes the action,
function, mounting place, working principle, fault
analysis, etc.
Select item [4. Help information on sensors] on the
main help menu, the screen will display the names of
12 common sensors as shown in Fig.2-16.
Select one of them and then press [ENTER] key. The
screen will display the related information about this
sensor. For example, if [1. Mass air flow sensor] is
selected, the screen display will be as shown in
Fig.2-17. Press [◄] or [►] key to turn to next page or
read the information about other sensors. Press [ESC]
to return to the upper level menu.
C-8
Multimeter
Fig.2-16
Fig.2-17