To Select Mv/Ps Operation By Program And Station; To Set Mv/Ps Start Delay; To Set Mv/Ps Operation During Station Delay - Toro TMC-424E User Manual

Hide thumbs Also See for TMC-424E:
Table of Contents

Advertisement

NOTE: A program must have the MV/PS control option enabled to permit individual stations
assigned to the program to be excluded from MV/PS operation. In other words, assigning MV/PS
operation by station is not applicable unless MV/PS operation for its assigned program is enabled.
• Master Valve/Pump Start Operation by Program
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to Special Functions
button to display MVA -- Y (Master Valve [program A] - Yes [on]).
3. Press the
4. To exclude the selected program from MV/PS operation, press the
MV[A] – N (Master Valve [program A] – No).
• Master Valve/Pump Start Operation by Station
button to display MVS -- N (Master Valve Stations – No).
1. Press the
2. To access this option, the option must first be enabled by pressing the
button to select MVS -- Y (Yes). By default, all station identifiers will be solid circles
or
(all enabled).
button to select MV -- Y 01 (Master Valve--Yes, station 01).
3. Press the
The station identifier will begin flashing.
4. Press the
button to exclude selected station, or press the
When excluded, the station identifier will change from solid to hollow. The next station identi-
fier in sequence will begin flashing.
5. Repeat the procedure in step 4 as needed for each station.
• To Set Pump Delay
This feature enables a delay period from 1 to 60 seconds to occur after the MS/PS circuit is activated,
and prior to the start of the first station in the watering sequence. This delay feature is often used in
conjunction with the Station Delay (SD) feature.
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to Special Functions
button (as needed) to display PD -- -- (Pump Delay Off).
3. Press the
4 . Press the
or
• To Set Pump Enable
This feature allows you to enable or disable MV/PS operation for the duration of a Station Delay
period.
1. Set the Program Switch to select program A, B, C, or D.
2. Turn the Function Dial to Special Functions
button as needed to display PE - - N (Pump Enable - No [Off]).
3. Press the
4. Press the
or
button to select the delay time value from 01 to 60 seconds.
button to select PE - - Y (Pump Enable - Yes [On]).
.
button to skip the station.
.
.
or
button to select
11