Use
General notes on use
The device must be placed on a flat and firm surface. Be careful not to stretch the arms out too
far, otherwise the device could tip over.
Make sure that all switches are in the "OFF" position and that all connections are secure.
Important:
panel" section.
Method
1.
Plug the plug into an earthed power socket. The device is protected against electrostatic dis-
charges and must be earthed for this protection to be fully effective.
2. Switch the device on on the main switch. The display panel will show "OFF" which means the
unit is in stand-by mode.
3. Attach the arms to the appropriate connection points. Then align the arms to ensure maximum
suction.
4. Press the switch
5. The up ( ) and down ( ) switches control the speed of the exhaust fan. It can be set to a value
from 20 % to 100 %. The speed of the extraction fan is saved with the switch
switch again switches the device to stand-by mode.
6. Insert a battery into the battery compartment of the extraction hood as described (see above).
Do not forget to close the battery compartment with the appropriate cover.
7. Press the LED switch (5a) to turn on the LED lamp. Press again to turn it off. When the LED
lamp is not needed, please turn it off to save power.
Replacing the HEPA filter and activated carbon filter
1.
The two filters should be replaced after approximately 3 months. However, the time of replace-
ment depends on how the device is used. It is recommended to replace the two filters at the
same time to keep the device working at its best.
2. Signs that indicate that the filters need to be replaced include the following:
a. HEPA filter has turned yellow or brown due to the absorption of a lot of particles and
smoke.
b. The filter performance has lowered because there are many particles in the filter.
c. The extraction performance has lowered because the filter is clogged.
3. To replace the HEPA filter, unlock the top cover of the device and pull out the old HEPA filter.
Unpack the new HEPA filter and then install it. Make sure that it is in the centre of the unit and
note the direction of the arrows.
4. Lock the top cover again to prevent air leakage and suction performance degradation.
5. To replace the activated carbon filter, pull out the old filter by the two white tabs. Unpack the
new carbon filter, then slide it into the unit.
Filter replacement notice
The device may show "FLT" on the display panel. In this case, the filters must be replaced as
described above.
If the replacement of the filter is not required or if the filter has just been replaced, please reset
the display by pressing and holding the up and down buttons at the same time until the display
goes off.
Switching the frequency
The device can run at 50 Hz or at 60 Hz. The frequency is set at the factory, but it can also be changed
manually. To do this, proceed as follows:
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
The operation of the switches is described in the "Explanation of the control
(on/off) to start suction.
Item 91934
; pressing this
Page 10
04 2023-1