Features

  • Laser guided targeting for aiming precision
  • Narrow distance-spot ratio for accurate results at greater distances
  • Safely measure hazardous or inaccessible objects
  • Standard 9V battery powers up to 12 hours of cumulative use
  • Auto-off after 15 seconds of inactivity

Specifications

Measurement Range: -58°F ~ 1022°F (-50°C ~ 550°C)
Accuracy: ±2% / ±2°C
Resolution: 0.1°F / °C
Maximum Output: < 1 mW
Wavelength: 630 - 670 nm
Distance-Spot Ratio: 12:1
Response Time: < 500 ms
Emissivity (Adjustable): 0.1-1.0
Battery: DC 9V

Function Diagram

Function Diagram

  1. LCD Display
  2. Unit(°C/°F)/DOWN
  3. Emissivity Adjustment Mode
  4. UP/Laser Pointer/Backlight
  5. Measurement Trigger
  6. Battery Compartment
  7. Laser Hole
  8. IR Sensor

Display Icon Key
Display Icon Key

  1. Low Battery
  2. Laser On
  3. Back-light On
  4. Continue Scanning
  5. °C / °F
  6. Temperature Result
  7. Max Temperature / Emissivity Result
  8. Max Temperature Sign
  9. Adjustable Emissivity Sign

Operation

Surface Temperature Measurement

warning NOTE: The Lasergrip cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.

  1. Once the battery is properly installed, press the measurement trigger to activate the device.
  2. Point the Lasergrip towards the surface of measurement.
  3. Press and hold the measurement trigger and the laser will activate for aiming guidance.
  4. Keep holding the trigger as you move the Lasergrip if you wish to live scan the surface area for temperature measurement.
  5. Once the laser is pointed to the desired point of measurement, release the trigger and the LCD display will lock the calculated temperature.
  6. Press the measurement trigger once again to make another measurement.


HOLD for continuous temperature reading


RELEASE to lock the temperature result

warning NOTE: The Lasergrip LCD will display 'OH' when the measured temperature is above the measurable range, and will display 'OL' when the measured temperature is below the measurable range.

Unit Conversion


To switch between units of temperature measurement, press the °C/°F button at any time while the Lasergrip is on.

Laser Activation


To activate and deactivate the laser, press the laser pointer On/Off button at any time while the Lasergrip is on.

Display Backlight Operation

To activate and deactivate the display backlight, press and hold measurement trigger and then press the display backlight On/Off button at the same time.

Emissivity Adjustment & Max Temperature


To adjust the emissivity value before measurement, press the emissivity adjustment mode button, then use the UP and DOWN buttons to navigate to the desired value. You may refer to the emissivity reference chart for correct surface emissivity values. To transfer into Max Temperature Mode, press the mode button again.

warning NOTE: The Lasergrip cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.

Battery Installation & Replacement

A new pre-installed 9V battery comes in protective plastic wrap inside your Lasergrip. Follow the steps below to properly install or replace the battery.

  1. Open the battery cover. For first-time use, take the battery out and remove the plastic wrapper. [Figure 1.1]
    Battery Installation & Replacement - Step 1
  2. Securely connect the battery to the battery terminals, making sure the leads and terminals are connected correctly. [Figure 1.2]
  3. Reinsert the battery back into the compartment.
  4. Close the battery cover, making sure that the wires are tucked inside the battery compartment. [Figure 1.3 ]
    Battery Installation & Replacement - Step 2

warning NOTE:

  • The low battery indicator will appear on the display when the power is running low. Immediately replace the battery when the icon appears.
  • Remove the battery before storing if the Lasergrip is not being used for a long time.

Distance-Spot Ratio

The Lasergrip 1080 measures surface temperature on the basis of distance to spot diameter ratio (D:S). As the distance between the thermometer and the surface increases, the total surface area measured will also increase. With a distance to spot ratio of 12:1 the surface area measured has a diameter of roughly 1/12 the distance.

For the most accurate results, make sure the target has a surface area of twice the corresponding spot diameter. Insufficient surface area will result in inaccurate results. The recommended distance to hold the Lasergrip from the surface of measurement is 14.17 in (36 cm). This creates a spot measurement area of 1.18 inches (3 cm) in diameter.

Distance (D) to Spot (S) size D:S = 12:1
Distance-Spot Ratio

Emissivity

The emissivity of a material is its efficiency in emitting thermal energy. Non-reflective surfaces have a higher emissivity (closer to 1) than reflective surfaces (closer to 0). Inaccurate results may occur when measuring reflective surfaces such as glass, polished wood, and granite.

To take accurate temperature measurement of reflective surfaces with low emissivity, adjust the emissivity value before measurement using the reference chart. Or, place a strip of masking tape over the surface and allow for it to adjust to the temperature of the surface for approximately 30 minutes. Measure the surface, scanning the taped section, eliminating the issue of inaccuracy.

Emissivity Of Materials

Emissivity Of Materials

Safety Use & Care

  • DO NOT point the laser-light at another person or animal.
  • DO NOT attempt to point laser-light at an aircraft.
  • Avoid direct/indirect eye contact with the laser-beam. Laser radiation may cause eye damage.
  • DO NOT view the beam with optical instruments.
  • In the vicinity of use, make any bystanders aware of the dangers of looking directly into the laser beam.
  • DO NOT allow children to operate the device.
  • Use a 9V battery when replacing the battery within the device. Make sure to insert the battery in accordance with the correct polarities.
  • ALWAYS remove the batteries when cleaning the device.
  • DO NOT use leaking batteries or dispose old batteries in fire.
  • Remove battery for storage if the device is not being used for a prolonged period of time.
  • DO NOT disassemble the device or tamper with internal components. Doing so will void any warranty.
  • DO NOT touch the lens or wipe it using anything other than a soft cloth or cotton swab.
  • Keep the thermometer away from electromagnetic fields produced by objects such as arc welders and induction heaters.
  • DO NOT expose the thermometer to direct sources of heat for extended periods of time.
  • The thermometer measures surface temperature, not internal temperature. Do not use the Lasergrip as a reliable source to measure body temperatures.


The device certification information is labeled directly on the device. The sticker is located on the left side of the Lasergrip.


The device warning and aperture safety information are also labeled directly on the device; the sticker is located on the right side of the Lasergrip.
Any updates to the product information (date of manufacturing and manufacturer address) will be added as adhesive overlays.

Questions or Concerns?
support@etekcity.com
(855)-686-3835

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Etekcity Lasergrip 1080 - Infrared Thermometer Manual

Advertisement

Need Assistance?

Do you have a question about the Lasergrip 1080 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents