Thank you for purchasing the Lasergrip 1022D Infrared Thermometer by Etekcity. This easy-to-use device lets you conveniently and accurately measure surface temperatures from a distance without the need of any direct contact. Should you have any questions or concerns, feel free to contact our helpful customer support team toll-free at 855.686.3835 or by email at support@etekcity.com.
THIS DEVICE PRODUCES CLASS 2 LASER RADIATION. USE EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. DO NOT LOOK INTO DIRECT OR REFLECTED LASER-LIGHT BEAM OR VIEW BEAM WITH OPTICAL INSTRUMENTS. DO NOT AIM LASER-LIGHT AT ANOTHER PERSON OR ANIMAL. LASER RADIATION MAY DAMAGE YOUR EYE. DO NOT DISASSEMBLE THE DEVICE.
Read all the instructions in this manual. Failure to comply with the instructions in this manual or use of the device, in ways other than the ones mentioned in this manual, may result in hazardous radiation exposure.
NOTE: The Lasergrip cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.
NOTE: The Lasergrip LCD will display 'OH' when the measured temperature is above the measurable range, and will display 'OL' when the measured temperature is below the measurable range.
To switch between units of temperature measurement, press the °C/°F button at any time while the Lasergrip is on.
To activate and deactivate the laser, press the laser pointer On/Off button at any time while the Lasergrip is on.
To activate and deactivate the display backlight, press the display backlight On/Off button at any time while the Lasergrip is on.
To adjust the emissivity value before measurement, press the emissivity adjustment mode button, then use the UP and DOWN buttons to navigate to the desired value. You may refer to the emissivity reference chart for correct surface emissivity values. To transfer into Max Temperature Mode, press the mode butt on again.
NOTE: The Lasergrip cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.
A low battery icon will appear on the LCD display when the Lasergrip's battery power is running low. Immediately replace the battery when the icon appears.
The Lasergrip 1022D measures surface temperature on the basis of distance to spot diameter ratio (D:S). As the distance between the thermometer and the surface increases, the total surface area measured will also increase. With a distance to spot ratio of 12:1 the surface area measured has a diameter of roughly 1/12 the distance.
For the most accurate results, make sure the two guidance lasers overlap at a single point. The space between the two lasers marks the the area of measurement. Insufficient surface area will result in inaccurate results. The recommended distance to hold the Lasergrip from the surface of measurement is 14.17 in (36 cm). This creates a spot measurement area of 1.18 inches (3 cm) in diameter.
The emissivity of a material is its efficiency in emitting thermal energy. Non-reflective surfaces have a higher emissivity (closer to 1) than reflective surfaces (closer to 0). Inaccurate results may occur when measuring reflective surfaces such as glass, polished wood, and garnite.
To take accurate temperature measurement of reflective surfaces with low emissivity, adjust the emissivity value before measurement using the reference chart. Or, place a strip of masking tape over the surface and allow for it to adjust to the temperature of the surface for approximately 30 minutes. Measure the surface, scanning the taped section, eliminating the issue of inaccuracy.
Material | Feature | Emissivity | Material | Feature | Emissivity |
Aluminium | Oxidized | 0.3 | Human Skin | 0.98 | |
Polished | 0.02-0.04 | Graphite | Oxidized | 0.20-0.60 | |
Brass | Oxidized | 0.5 | Plastic | Nontransparent | 0.95 |
Polished | 0.02-0.05 | Rubber | 0.95 | ||
Gold | 0.01-0.10 | Plastic Cement | 0.85-0.95 | ||
Iron | Oxidized | 0.7 | Concrete | 0.95 | |
Steel | Oxidized | 0.70-0.90 | Cement | 0.96 | |
Asbestos | 0.95 | Soil | 0.90-0.98 | ||
Plaster | 0.80-0.90 | Mortar | 0.89-0.91 | ||
Asphalt | 0.95 | Brick | 0.90-0.96 | ||
Rock | 0.7 | Marble | 0.94 | ||
Wood | 0.90-0.95 | Textile | 0.90 | ||
Charcoal | Powered | 0.96 | Paper | 0.95 | |
Carbon | 0.85 | Sand | 0.90 | ||
Lacquer work | Lackluster | 0.97 | Clay | 0.92-0.96 | |
Carbon Cement | 0.90 | Sand | 0.9 | ||
Soap Bubble | 0.75-0.80 | Glass | 0.85-0.92 | ||
Water | 0.93 | Textile | 0.95 | ||
Snow | 0.83-0.90 | Heated Food | 0.95 | ||
Ice | 0.96-0.98 | Plastic | 0.95 | ||
Frozen Foods | 0.95 | Oil | 0.94 | ||
Ceramics | 0.95 | Steel and iron | 0.80 | ||
Limestone | 0.98 | Wool | Natural | 0.94 | |
Paint | 0.93 | Lead | Oxidized | 0.5 |
The device certification information is labeled directly on the device. The sticker is located on the left side of the Lasergrip.
The device warning and aperture safety information are also labeled directly on the device; the sticker is located on the right side of the Lasergrip.
Any updates to the product information (date of manufacturing and manufacturer address) will be added as adhesive overlays.
1 x Lasergrip 1022D
1 x 9V DC Battery
1 x User Manual
If you encounter any issues or have any questions regarding your new product, please contact our helpful Customer Support Team. Your satisfaction is our goal!
Etekcity Corporation
1202 N Miller St., Suite A
Anaheim, CA 92806 USA
Toll Free: (855) 686-3835
Email: support@etekcity.com
Support Hours
Mon - Fri 9:00 am - 5:00 pm PST/PDT
*Please have your order confirmation number ready before contacting Customer Support.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Etekcity Lasergrip 1022D - Infrared Thermometer Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the Lasergrip 1022D that isn't answered in the manual? Leave your question here.