Etekcity Lasergrip 1022 - Infrared Thermometer Manual

Etekcity Lasergrip 1022 - Infrared Thermometer Manual

Advertisement

Etekcity Lasergrip 1022 - Infrared Thermometer Manual

Introduction

This easy-to-use device lets you conveniently and accurately measure surface temperatures from a distance without the need of any direct contact. Should you have any questions or concerns, feel free to contact our helpful customer support team toll-free at 855.686.3835 or by email at support@etekcity.com.

Features & Specifications

  • Laser guided targeting for aiming precision
  • Narrow distance-spot ratio for accurate results at greater distances
  • Safely measure hazardous or inaccessible objects
  • Standard 9V battery powers up to 12 hours of cumulative use
  • Auto-off after 15 seconds of inactivity
  • Measurement Range: -58°F ~ 1022°F (-50°C ~ 550°C)
  • Accuracy: ±2% / ±2°C
  • Resolution: 0.1°F/°C
  • Maximum Output: < 1 mW
  • Wavelength: 630 - 670 nm
  • Distance-Spot Ratio: 12:1
  • Response Time: < 500 ms
  • Emissivity(Adjustable): 0.1-1.0
  • Battery: DC 9V

Function Diagram

Function Diagram

  1. LCD Display
  2. Display Backlight On/Off
  3. Laser Pointer / UP
  4. Unit (°C/°F) / DOWN
  5. Emissivity Adjustment/Max Temperatures
  6. Laser Hole
  7. IR Sensor
  8. Measurement Trigger
  9. Battery Compartment

Display Icon Key

Display Icon Key

  1. Low Battery
  2. Laser On
  3. Back-light On
  4. Continue Scanning
  5. °C/°F
  6. Temperature Result
  7. Max Temperature / Emissivity Result
  8. Max Temperature Sign
  9. Adjustable Emissivity Sign

Operation

Surface Temperature Measurement

NOTE: The Lasergrip cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.

  1. Once the battery is properly installed, press the measurement trigger to activate the device.
  2. Point the Lasergrip towards the surface of measurement.
  3. Press and hold the measurement trigger and the laser will activate for aiming guidance.
  4. Keep holding the trigger as you move the Lasergrip if you wish to live scan the surface area for temperature measurement.
  5. Once the laser is pointed to the desired point of measurement, release the trigger and the LCD display will lock the calculated temperature.
  6. Press the measurement trigger once again to make another measurement.

NOTE: The Lasergrip LCD will display 'OH' when the measured temperature is above the measurable range, and will display 'OL' when the measured temperature is below the measurable range.

Unit Conversion


To switch between units of temperature measurement, press the °C/°F button at any time while the Lasergrip is on.

Laser Activation


To activate and deactivate the laser, press the laser pointer On/Off button at any time while the Lasergrip is on.

Display Backlight Operation


To activate and deactivate the display backlight, press the display backlight On/Off button at any time while the Lasergrip is on.

Emissivity Adjustment Mode


To adjust the emissivity value before measurement, press the emissivity adjustment mode button, then use the UP and DOWN buttons to navigate to the desired value. You may refer to the emissivity reference chart for correct surface emissivity values.

Battery Replacement

A low battery icon will appear on the LCD display when the Lasergrip's battery power is running low. Immediately replace the battery when the icon appears.

  1. Open the battery compartment and remove the used battery. Dispose the used battery properly.
  2. Connect a new DC 9V battery, making sure it's under the correct polarity.
    Battery Replacement - Step 1 - Check the polarity
  3. Insert the battery into the compartment and close the compartment lid, making sure the wiring is not being pinched by the compartment lid.
    Battery Replacement - Step 2 - Insert the battery

Distance-Spot Ratio

The Lasergrip 1022 measures surface temperature on the basis of distance to spot diameter ratio (D:S). As the distance between the thermometer and the surface increases, the total surface area measured will also increase. With a distance to spot ratio of 12:1 the surface area measured has a diameter of roughly 1/12 the distance.

For the most accurate results, make sure the target has a surface area of twice the corresponding spot diameter. Insufficient surface area will result in inaccurate results. The recommended distance to hold the Lasergrip from the surface of measurement is 14.17 in (36 cm). This creates a spot measurement area of 1.18 inches (3 cm) in diameter.
Distance-Spot Ratio
Distance (D) to Spot (S) size D:S = 12:1

Emissivity

The emissivity of a material is its efficiency in emitting thermal energy. Non-reflective surfaces have a higher emissivity (closer to 1) than reflective surfaces (closer to 0). Inaccurate results may occur when measuring reflective surfaces such as glass, polished wood, and granite.

To take accurate temperature measurement of reflective surfaces with low emissivity, adjust the emissivity value before measurement using the reference chart. Or, place a strip of masking tape over the surface and allow for it to adjust to the temperature of the surface for approximately 30 minutes. Measure the surface, scanning the taped section, eliminating the issue of inaccuracy.

Emissivity Of Materials

Material Feature Emissivity Material Feature Emissivity
Aluminium Oxidized 0.3 Paint 0.93
Polished 0.02-0.04 Graphite Oxidized 0.20-0.60
Brass Oxidized 0.5 Plastic Non-transparent 0.95
Polished 0.02-0.05 Rubber 0.95
Gold 0.01-0.10 Plastic Cement 0.85-0.95
Iron Oxidized 0.7 Concrete 0.95
Steel Oxidized 0.70-0.90 Cement 0.96
Asbestos 0.95 Soil 0.90-0.98
Plaster 0.80-0.90 Mortar 0.89-0.91
Asphalt 0.95 Brick 0.90-0.96
Rock 0.7 Marble 0.94
Wood 0.90-0.95 Textile 0.90
Charcoal Powered 0.96 Paper 0.95
Carbon 0.85 Sand 0.90
Lacquerwork Lackluster 0.97 Clay 0.92-0.96
Carbon Cement 0.90 Glass 0.85-0.92
Soap Bubble 0.75-0.80 Textile 0.95
Water 0.93 Heated Food 0.95
Snow 0.83-0.90 Plastic 0.95
Ice 0.96-0.98 Oil O.94
Frozen Foods 0.95 Steel and iron 0.80
Ceramics 0.95 Wool Natural O.94
Limestone 0.98 Lead Oxidized 0.5

The device certification information is labeled directly on the device. The sticker is located on the left side of the Lasergrip.
Device certification information label

The device warning and aperture safety information are also labeled directly on the device; the sticker is located on the right side of the Lasergrip.
Device warning label

Any updates to the product information (date of manufacturing and manufacturer address) will be added as adhesive overlays.

Package Contents

1 x Etekcity Lasergrip 1022 Infrared Thermometer
1 x 9V DC Battery
1 x User Manual

Safety Use & Care

AVOID EXPOSURE
LASER RADIATION IS EMITTED FROM THIS APERATURE.


LASER RADIATION - DO NOT STARE INTO BEAM
WAVELENGTH 630-670nm
MAXIMUM OUTPUT <1mW
CLASS II LASER PRODUCT


THIS DEVICE PRODUCES CLASS 2 LASER RADIATION. THE LASER LIGHT IS INVISIBLE TO THE HUMAN EYE. USE EXTREME CAUTION AT ALL TIMES WHEN LASER IS IN USE. DO NOT LOOK INTO DIRECT OR REFLECTED LASER-LIGHT BEAM OR VIEW BEAM WITH OPTICAL INSTRUMENTS. DO NOT AIM LASER-LIGHT AT ANOTHER PERSON OR ANIMAL. LASER RADIATION MAY DAMAGE YOUR EYE. DO NOT DISASSEMBLE THE DEVICE.


Read all the instructions in this manual. Failure to comply with the instructions in this manual or use of the device, in ways other than the ones mentioned in this manual, may result in hazardous radiation exposure.

  • DO NOT point the laser-light at another person or animal.
  • DO NOT attempt to point laser-light at an aircraft.
  • Avoid direct/indirect eye contact with the laser-beam. Laser radiation may cause damage to eyes.
  • DO NOT view the beam with optical instruments.
  • In the vicinity of use, make any bystanders aware of the dangers of looking directly into the laser pointer.
  • DO NOT allow children to operate the device.
  • Use a 9V battery when replacing the battery within the device. Make sure to insert the battery in accordance with the correct polarities indicated.
  • ALWAYS remove the batteries when cleaning the device.
  • DO NOT use leaking batteries or dispose old batteries in fire.
  • Remove the battery for storage if the device is not being used for a prolonged period of time.
  • DO NOT disassemble the device or tamper with internal components. Doing so will void any warranty.
  • DO NOT touch the lens or wipe it using anything other than a soft cloth or cotton swab.
  • Keep the thermometer away from electromagnetic fields produced by objects such as arc welders and induction heaters.
  • DO NOT expose the thermometer to direct sources of heat for extended periods of time.
  • The thermometer measures surface temperature, not internal temperature. Do not use the Lasergrip as a reliable source to measure body temperatures.

Customer Support

If you encounter any issues or have any questions about your new product, please contact our helpful Customer Support Team.

Etekcity Corporation
1202 N Miller St., Suite A
Anaheim, CA 92806

Toll Free: (855) 686-3835
Email: support®etekcity.com

Support Hours
Mon - Fri 9:00 am - 5:00 pm PST/PDT

*Please have your invoice and order ID ready before contacting Customer Support.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Etekcity Lasergrip 1022 - Infrared Thermometer Manual

Advertisement

Need Assistance?

Do you have a question about the Lasergrip 1022 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents