Etekcity Lasergrip 1030D - Infrared Thermometer Manual

Etekcity Lasergrip 1030D - Infrared Thermometer Manual

Advertisement

Etekcity Lasergrip 1030D - Infrared Thermometer Manual

Package Contents

1 x Lasergrip 1030D
1 x 9V DC Battery
1 x User Manual

Main Functions

Main Functions Overview

  1. LCD display
  2. Right button
  3. SET °C/°F selection
  4. Left button
  5. Laser hole
  6. R sensor
  7. Measurement trigger

Set-Up

  1. Open the battery compartment and remove the battery notice strip.
  2. Remove the battery from the compartment and unwrap it from its packaging.
  3. Place the battery back into the compartment, connecting the battery under the correct polarity.
  4. Re-seal the battery compartment, making sure the inside wiring does not get pinched by the compartment lid.

Operation

Surface Temperature Measurement

  1. Point the Lasergrip towards the desired surface to be measured.
  2. Press and hold the measurement trigger The scan symbol will appear on display while you are taking your measurement.
  3. Release the measurement trigger; the temperature reading will appear on the LCD display.
  4. For continuous measurements, press and hold the measurement trigger while scanning the measured surface.
  5. The Lasergrip will automatically turn off after 1 minute of inactivity.

NOTE

  • The Lasergrip cannot measure the temperature of objects behind glass. Inaccuracy may also occur when exposed to steam, dust or any other contaminants in the air.
  • The Lasergrip will display "OH" if the measured temperature exceeds the maximum temperature range and will display "OL" when the measured temperature is below the minimum temperature range.

Temperature Filtering

  1. Press and hold the measurement trigger to take a temperature reading, don't release the trigger then press SET °C/°F.
  2. The display will show the temperature next to "REF", meaning the measured temperature is now the reference value. Release the measurement trigger once the reference temperature has been set.
  3. Press and to move the on screen arrow to the corresponding temperature range. The range can be adjusted to read temperature differences in increments of 0.5°C/1°F, 3.0°C/5°F, and 5.5°C/10°F.
  4. Once the temperature range has been set, press and hold the measurement trigger to measure a surface. If the measured temperature is lower than the selected range, the screen will light up blue. If the measured temperature is higher than the selected range, the screen will light up red.
  5. Move the arrow to "OFF" by using and to turn off the temperature filter function.

Emissivity

The emissivity of a material is its efficiency in emitting thermal energy. Non-reflective surfaces have a higher emissivity (closer to 1) than reflective surfaces (closer to 0). Inaccurate results may occur when measuring reflective surfaces such as glass, polished wood, and granite.
Most organic materials and painted or oxidized surfaces have an emissivity of 0.95. Other materials, such as polished metal surfaces, have a different emissivity level, which should be taken into account for accurate temperature measurement. One way to improve accuracy is to cover the surface with non reflective masking tape or flat black paint, and then measure when the temperature reaches that of the underlying surface.

Distance-to-Spot Ratio

As the distance between the thermometers and the target increases, the surface area measured also increases. With a distance-spot ratio 12:1, the area measured also has a diameter of roughly 1/12 the distance. (i.e. When standing 12 feet away from the surface being measured, only a 1 foot diameter on that surface is measured.) For the most accurate results, make sure the target has a surface area of twice the corresponding spot size at the given distance.

Maintenance

General Maintenace

  1. Use compressed air to remove any dust or particles on the Lasergrip lens.
  2. Use a soft bristle brush to remove any debris from the lens, followed by a clean, wet cloth. Dry the lens with a soft, clean cloth immediately after.
  3. Clean the included case with a damp sponge or cloth and mild detergent.

NOTE

  • Do not use soap or detergent to clean the lens.
  • Do not immerse the unit in water or liquid detergents.

Battery Replacement

A low battery icon will appear on the LCD display when the Lasergrip's battery power is running low. Immediately replace the battery when the icon appears.

  1. Open the battery compartment and remove the used battery. Properly dispose the used battery.
  2. Connect a new DC 9V battery, ensuring that it is under the correct polarity.
  3. Insert the battery into the compartment and close the lid. Make sure that the wiring is not pinched while closing the lid.

Specifications

Measurement Range -58° ~ 1022°F (-50° ~ 550°C)
Accuracy ≥ 100°C ±2%/≤ 100°C ±2%
Response Time ≤ 500ms
Emissivity 0.95
Distance to Spot Ratio 12:1
Storage Temperature -4° ~ 122°F (-20° ~ 50°C)
Operating Temperature 32° ~ 122°F (0° ~ 50°C)

Safety Information



This device produces CLASS 2 laser radiation. Use extreme caution at all times when laser is in use. Do not look into direct or reflected laser-light beam or view beam with optical instruments. Do not aim laser-light at another person or animal. Laser radiation may damage your eye. Do not disassemble the device.

Please read and comply with all of the instructions and warnings provided in this manual before using the product. Failure to comply with the instructions and warnings provided herein may result in inaccurate results and/or damage to the product itself.

  • DO NOT point the laser-light at another person or animal.
  • DO NOT attempt to point the laser-light at an aircraft.
  • Avoid direct/indirect eye contact with the laser beam. Laser radiation may cause eye damage.
  • DO NOT view the beam with optical instruments.
  • In the vicinity of use, make any bystanders aware of the dangers of looking directly into the laser beam.
  • DO NOT allow children to operate the device.
  • Use a 9V battery when replacing the battery within the device. Make sure to insert the battery in accordance with the correct polarities.
  • ALWAYS remove the battery when cleaning the device.
  • DO NOT use leaking batteries or dispose old batteries in fire.
  • Remove the battery for storage if the device is not being used for a prolonged period of time.
  • DO NOT disassemble the device or tamper with internal components. Doing so will void any warranty.
  • DO NOT touch the lens or wipe it using anything other than a soft cloth or cotton swab.
  • Keep the thermometer away from electromagnetic fields produced by objects such as arc welders and induction heaters.
  • DO NOT expose the thermometer to direct sources of heat for extended periods of time.
  • The thermometer measures surface temperature, not internal temperature. Do not use the Lasergrip as a reliable source to measure body temperatures.

The device certification information is labeled directly on the device. The sticker is located on the left side of the Lasergrip.

The device warning and aperture safety information are also labeled directly on the device; the sticker is located on the right side of the Lasergrip. Any updates to the product information (date of manufacturing and manufacturer address) will be added as adhesive overlays.

Customer Support

If you encounter any issues or have any questions about your new product, please contact our helpful Customer Support Team.

Etekcity Corporation
1202 N Miller St., Suite A
Anaheim, CA 92806
Toll Free: (855) 686-3835
Email: support@etekcity.com
Support Hours
Mon - Fri,
9:00 am 5:00 pm PST/PDT
*Please have your invoice and order ID ready before contacting Customer Support.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Etekcity Lasergrip 1030D - Infrared Thermometer Manual

Advertisement

Need Assistance?

Do you have a question about the Lasergrip 1030D that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents