Cooling performance data - 2 ton
Table 22: Cooling performance data - TCE2B24S21S with indoor coil XAFA24BXXN1
Air
IDCFM
600
temperature
ID DB
80
entering
(°F)
outdoor unit
ID WB
57
(°F)
(°F)
55
T.C.
21.9
S.C.
21.9
Kw
1.23
65
T.C.
21.3
S.C.
21.3
Kw
1.43
75
T.C.
20.7
S.C.
20.7
Kw
1.54
85
T.C.
20.1
S.C.
20.1
Kw
1.65
95
T.C.
19.4
S.C.
19.4
Kw
1.84
105
T.C.
18.7
S.C.
18.7
Kw
2.05
115
T.C.
17.9
S.C.
17.9
Kw
2.30
125
T.C.
16.3
S.C.
16.3
Kw
2.61
Cooling performance data notes
• All capacities include indoor fan heat. kW values are for the system (outdoor + indoor).
• Green shaded cells are ACCA (TVA) conditions.
• Blue shaded cells are AHRI conditions.
Multipliers for determining the performance with other
indoor sections
Note: For dry bulb temperatures different than those listed (between 73°F to 87°F), sensible
capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and
decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Cool multiplier airhandler - 2 ton
Table 23: Cool multiplier air handler - 2 ton
Air handler model
Indoor coil model
—
CF/CM/CU30B
—
CF/CM30A
—
CF/CM30C
—
XAF/XAUA24B
98
Coleman Technical Guide: LX Series TCE2B Models - 14.3 SEER2 Split-System Air Conditioner - Single-Phase
800
80
75
80
80
80
62
62
67
72
57
23.8
23.7
26.1
28.3
24.0
19.8
16.9
16.7
13.5
24.0
1.22
1.22
1.21
1.20
1.30
23.1
23.0
25.3
27.7
23.1
19.3
16.4
16.4
13.4
23.1
1.41
1.41
1.38
1.35
1.50
22.4
22.3
24.5
26.8
22.5
18.9
16.1
16.1
13.1
22.5
1.53
1.53
1.51
1.48
1.61
21.6
21.5
23.6
25.9
21.8
18.5
15.7
15.7
12.7
21.8
1.64
1.64
1.63
1.61
1.73
20.6
20.5
22.6
24.8
20.9
18.0
15.2
15.2
12.3
20.9
1.82
1.83
1.81
1.79
1.91
19.6
19.6
21.6
23.7
20.2
17.7
14.9
14.9
11.9
20.2
2.04
2.05
2.02
2.01
2.12
18.5
18.5
20.4
22.3
19.3
17.3
14.5
14.5
11.5
19.3
2.30
2.30
2.27
2.25
2.37
17.0
17.0
18.7
20.7
17.4
17.0
14.0
13.6
10.7
17.4
2.61
2.62
2.61
2.57
2.67
Total capacity
1.00
1.00
1.00
1.00
Johnson Controls Ducted Systems
1000
80
75
80
80
80
62
62
67
72
57
24.9
24.9
27.2
29.4
25.5
22.6
18.9
18.6
14.5
25.5
1.31
1.31
1.29
1.25
1.38
24.2
24.1
26.4
28.8
24.3
21.8
18.2
18.2
14.6
24.3
1.48
1.48
1.45
1.41
1.56
23.3
23.3
25.6
27.9
23.6
21.4
17.9
17.9
14.2
23.6
1.60
1.60
1.58
1.55
1.68
22.4
22.4
24.6
26.9
22.9
20.9
17.5
17.5
13.8
22.9
1.72
1.72
1.71
1.68
1.81
21.4
21.4
23.5
25.7
21.9
20.4
17.0
17.0
13.4
21.9
1.90
1.91
1.89
1.87
1.99
20.2
20.3
22.3
24.4
21.1
20.2
16.7
16.7
13.0
21.1
2.12
2.12
2.10
2.09
2.20
19.3
19.1
21.0
22.9
20.1
19.3
16.4
16.4
12.6
20.1
2.37
2.38
2.35
2.33
2.44
18.2
17.5
19.5
21.2
18.1
18.2
16.0
15.9
11.6
18.1
2.67
2.69
2.66
2.65
2.75
Sensible capacity
0.98
0.98
0.98
1
80
75
80
80
62
62
67
72
25.7
25.5
27.8
29.8
24.9
20.7
20.1
15.2
1.40
1.40
1.36
1.32
24.7
24.7
27.1
29.4
23.8
19.8
19.8
15.5
1.56
1.56
1.52
1.48
23.8
23.8
26.1
28.5
23.5
19.4
19.4
15.1
1.68
1.68
1.66
1.63
22.9
22.9
25.1
27.4
22.9
19.0
19.0
14.7
1.81
1.81
1.79
1.76
21.9
21.8
23.9
26.1
21.9
18.5
18.4
14.2
1.99
1.99
1.97
1.96
21.1
20.6
22.7
24.8
21.1
18.3
18.3
13.9
2.20
2.20
2.19
2.17
20.1
19.3
21.3
23.2
20.1
17.9
18.0
13.5
2.44
2.46
2.43
2.42
19.0
17.7
19.8
21.4
19.0
17.7
17.9
12.3
2.74
2.77
2.75
2.73
kW
1
1
1
1