Performance Data - 2.5 Ton; Condenser Only Performance Data - 2.5 Ton; Condenser Only Performance Data Notes; Cooling Performance Data - 2.5 Ton - Coleman LX Series Technical Manual

4.3 seer2 split-system air conditioner - single-phase
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

Performance data - 2.5 ton

See the following tables for performance and multiplier data for the TCE2B30S21S unit.

Condenser only performance data - 2.5 ton

Table 25: TCE2B30S21S condenser table
Saturated suction
at compressor
Temperature
Pressure
55 °F
(°F)
(psig)
MBH
35
107
29.6
1.20
40
118
32.6
1.20
45
130
35.7
1.21
50
142
39.1
1.23
55
156
42.7
1.24

Condenser only performance data notes

• For outdoor unit (condenser) performance only. Data does not include the effects of air
handler power or heat.
• Performance based on 15°F subcooling and 15°F superheat at the outdoor unit base valves:
a. Increase capacity by 1% for each 2°F increase in subcooling.
b. Decrease capacity by 1% for each 2°F decrease in subcooling.
• Maximum recommended condensing temperature is 140°F.

Cooling performance data - 2.5 ton

Table 26: Cooling performance data - TCE2B30S21S with indoor coil XAFB30CXXN1
Air
IDCFM
800
temperature
ID DB
80
entering
(°F)
outdoor unit
ID WB
57
(°F)
(°F)
55
T.C.
28.7
S.C.
28.7
Kw
1.51
65
T.C.
27.7
S.C.
27.7
Kw
1.66
75
T.C.
26.8
S.C.
26.8
Kw
1.85
85
T.C.
25.8
S.C.
25.8
Kw
2.05
95
T.C.
25.2
S.C.
25.2
Kw
2.28
105
T.C.
24.0
S.C.
24.0
Kw
2.51
115
T.C.
22.7
S.C.
22.7
Kw
2.78
Coleman Technical Guide: LX Series TCE2B Models - 14.3 SEER2 Split-System Air Conditioner - Single-Phase
65 °F
75 °F
kW
MBH
kW
MBH
kW
28.2
1.39
26.6
1.58
31.0
1.40
29.3
1.59
34.0
1.41
32.1
1.60
37.2
1.42
35.1
1.61
40.6
1.43
38.4
1.63
1000
80
75
80
80
80
62
62
67
72
57
30.0
29.8
31.5
33.5
30.4
25.7
21.7
20.9
16.2
30.4
1.49
1.49
1.47
1.45
1.58
29.8
29.6
32.4
35.1
29.5
25.4
21.5
21.5
17.4
29.5
1.66
1.66
1.66
1.66
1.74
28.7
28.6
31.3
34.2
28.5
24.6
20.8
20.7
16.7
28.5
1.85
1.85
1.85
1.86
1.94
27.4
27.4
30.0
32.8
27.4
24.0
20.2
20.1
16.0
27.4
2.05
2.05
2.05
2.06
2.14
26.4
26.4
28.9
31.6
26.7
24.0
20.0
20.0
15.9
26.7
2.28
2.28
2.29
2.30
2.37
24.7
24.8
27.3
29.9
25.4
23.1
19.2
19.2
15.2
25.4
2.51
2.52
2.53
2.54
2.61
22.9
23.2
25.5
28.0
23.9
22.1
18.5
18.4
14.4
23.9
2.78
2.78
2.80
2.82
2.88
Johnson Controls Ducted Systems
Outdoor ambient temperature
85 °F
95 °F
105 °F
MBH
kW
MBH
kW
MBH
24.9
1.78
23.0
1.99
21.1
27.4
1.79
25.4
2.00
23.3
30.1
1.80
27.9
2.02
25.7
32.9
1.81
30.6
2.03
28.2
36.0
1.83
33.5
2.06
30.9
80
75
80
80
62
62
67
72
31.2
31.1
33.6
35.4
28.5
23.9
23.4
18.4
1.56
1.57
1.55
1.54
30.8
30.6
33.5
36.2
28.1
23.4
23.3
18.5
1.74
1.75
1.75
1.75
29.6
29.5
32.3
35.1
27.3
22.7
22.6
17.8
1.94
1.94
1.94
1.95
28.1
28.2
30.8
33.6
26.5
22.0
21.9
17.1
2.14
2.14
2.14
2.15
26.8
27.1
29.7
32.4
26.3
21.9
21.9
17.1
2.37
2.37
2.38
2.39
25.4
25.4
28.0
30.6
25.4
21.2
21.1
16.3
2.61
2.61
2.62
2.64
23.9
23.7
26.1
28.6
23.9
20.4
20.4
15.6
2.88
2.88
2.89
2.91
115 °F
125 °F
kW
MBH
kW
MBH
kW
2.23
19.1
2.50
17.1
2.82
2.24
21.2
2.52
19.1
2.84
2.26
23.4
2.54
21.2
2.87
2.28
25.8
2.56
23.4
2.89
2.31
28.3
2.59
25.7
2.92
1200
80
80
75
80
80
57
62
62
67
72
31.5
32.2
31.9
34.9
36.7
31.5
30.6
25.5
25.0
19.6
1.64
1.64
1.64
1.63
1.63
30.8
31.2
31.2
34.1
36.8
30.8
30.0
25.0
24.9
19.4
1.83
1.83
1.84
1.84
1.84
29.7
29.9
30.1
32.9
35.7
29.7
29.3
24.3
24.2
18.7
2.02
2.03
2.03
2.03
2.04
28.5
28.6
28.7
31.4
34.2
28.5
28.6
23.6
23.5
18.1
2.23
2.23
2.23
2.23
2.24
27.8
27.9
27.5
30.2
32.9
27.8
27.9
23.6
23.6
18.1
2.46
2.46
2.46
2.47
2.48
26.4
26.4
25.8
28.4
31.0
26.4
26.4
22.8
22.8
17.3
2.70
2.70
2.70
2.71
2.73
24.9
24.8
23.9
26.4
28.9
24.9
24.8
22.0
22.0
16.5
2.97
2.97
2.97
2.98
3.01
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents