Emptying The Waste Tank - MAHLE MCX-1 Operation Manual

Multiple coolant exchanger
Table of Contents

Advertisement

The Waste Tank can be emptied two different ways
A. The Waste Tank can be removed from the MCX-1 and transported to the area where it is to
be emptied. A quick connect coupler is installed on the black hose to make this
disconnection quick and clean.
B. The MCX-1 can be used to pump the waste coolant directly from the Waste Tank into
another waste collection tank. A 12 volt battery will be required to power the MCX-1.
Green Hose
1. Install the Wand on the black hose.
2. Turn control valve to EMPTY WASTE TANK.
3. Press the top of the EMPTY WASTE TANK selector switch to start the pump.
4. Hold the Wand over the Bulk Waste Container and open the valve.
5. Waste coolant will be pumped directly from the MCX-1 Waste Tank into the Bulk Waste
Container.
6. The Waste Tank will empty and the pump will shut off.
controls this function.
7. Close the valve on the Wand immediately after waste tank is emptied.
8. Press bottom of the EMPTY WASTE TANK selector switch to stop the pump.
Note: The Waste Tank has a float switch which detects when the tank is empty and shuts
off the waste pump.

EMPTYING THE WASTE TANK

Black Hose
Page 14
Bulk Waste Container
A float switch in the Waste Tank