Hoses Emptying; Air Purge; Vessel Filling; Pressures Zero - MAHLE AIR-NEX 9380 Service Manual

Table of Contents

Advertisement

14.2

Hoses emptying

To empty the charge hoses completely perform the hoses
To empty the charge hoses completely perform the hoses
emptying phase.
Select the hoses emptying function from the menu. Wait
Select the hoses emptying function from the menu. Wait
the end of the procedure.
14.3

Air purge

In the main menu select MAINTENANCE and press "AIR
PURGE".
By selecting this function, it is possible to manually
By selecting this function, it is possible to manually
discharge the non condensable gases by means of the
discharge the non condensable gases by means of the
solenoid valve.
Automatically every 7 days, the station will show the
Automatically every 7 days, the station will show the
possibility to automatically check (automatic function
possibility to automatically check (automatic
named AIR PURGE SYSTEM) for condensable gases.
named AIR PURGE SYSTEM) for condensable gases.
14.4

Vessel filling

In the main menu select MAINTENANCE and press
In the main menu select MAINTENANCE and press
"VESSEL FILLING".
Set the quantity of refrigerant to fill and follow the guided
Set the quantity of refrigerant to fill and follow the guided
procedure shown on the display.
The set value is limited to avoid to fill too much the internal
to avoid to fill too much the internal
cylinder.
Only when the message appears asking to connect the
Only when the message appears asking to connect the
charge tank, connect the LP quick coupler (colour
the unit to an external refrigerant tank using the supplied
the unit to an external refrigerant tank using the supplied
adaptor.
When the message occurs open the coupler by turning the
knob clockwise. Open the valve on the external tank.
knob clockwise. Open the valve on the external tank.
Just right before reaching the planned quantity of
Just right before reaching the planned quantity of
refrigerant, the unit will stop and ask the user to close the
refrigerant, the unit will stop and ask the user to close the
external refrigerant tank. Then, the device will continue the
external refrigerant tank. Then, the device will continue the
recovery from the hoses and ends when these are empty.
recovery from the hoses and ends when these are empty.
Hence, it is necessary to open the LP quick-coupler and
disconnect it from the external tank.
Thanks to the ECO-LOCK CONNECT function, the
refrigerant - usually kept between the cylinder fitting and
usually kept between the cylinder fitting and the
hose quick-coupler until the end of the process - will not be
released in the environment.
There may be two types of source tanks: with plunger and
There may be two types of source tanks: with plunger and
without plunger.
Tanks with plunger shall remain upright to be able to
shall remain upright to be able to
transfer liquid refrigerant; for this type of tanks connect to
the L (liquid) coupler.
Tanks without plunger have only one valve, so they must
have only one valve, so they must
be turned upside down to transfer the liquid refrigerant.
be turned upside down to transfer the liquid refrigerant.
© MAHLE
NCE and press "AIR
quick coupler (colour blue) of
n the coupler by turning the
coupler and
CONNECT function, the
will not be
r this type of tanks connect to
The LP gauge indicates the pressure inside the external tank.
gauge indicates the pressure inside the external tank.
After some minutes the unit will automatically end the function.
he unit will automatically end the function.
At the end the weight of the charged refrigerant will be displayed.
At the end the weight of the charged refrigerant will be displayed.
14.5

Pressures zero

In the main menu select MAINTENANCE and press "PRESSURES
In the main menu select MAINTENANCE and press "PRESSURES
ZERO".
This function allows to determine and store the atmospheric
This function allows to determine and store the at
pressure value.
We recommend running this procedure every time the A/C service
We recommend running this procedure every time the A/C service
station will be moved from a location to another with a different
moved from a location to another with a different
altitude.
14.6

Self leak test

In the main menu select MAINTENANCE and p
In the main menu select MAINTENANCE and press "SELF LEAK
TEST".
A leak test is carried out on the internal components of A/C service
carried out on the internal components of A/C service
station.
This phase includes:
Hoses emptying
Vacuum test
This test allows to check the tightness of the internal circuits of the
This test allows to check the tightness of the internal circuits of the
equipment from the solenoid valve, allowing the fluid outflow from
equipment from the solenoid valve, allowing the fluid outflow from
the internal cylinder, to the manifold, (metallic component housing
internal cylinder, to the manifold, (metallic component housing
the check solenoid valves) to the compressor infeed, including the
the check solenoid valves) to the compressor infeed, including the
dryer filter leak test.
In case of failed leak test, it is necessary to check the charge hoses
In case of failed leak test, it is necessary to check the charge hoses
conditions
and the quick couplers leak, and make the possible
repair and then repeat the test.
14.7

LONG LIFE PUMP

The A/C service station is equipped with a special function named
The A/C service station is equipped with a special function named
LONG LIFE PUMP that enables to optimize the vacuum pump oil
PUMP that enables to optimize the vacuum pump oil
use by avoiding the replacement every 60 hours of operation.
use by avoiding the replacement every 60 hour
LONG LIFE PUMP is a special function allowing to extend even to
PUMP is a special function allowing to extend even to
1000 hours the life of the pump oil used in the station.
1000 hours the life of the pump oil used in the station. LONG LIFE
PUMP function performance is suggested at the end of 60
PUMP function performance is suggested at the end of 60-hour
operation intervals of the vacuum pump and can
operation intervals of the vacuum pump and can be manually
activated in the MAINTENANCE menu pressing LONG LIFE PUMP.
activated in the MAINTENANCE menu pressing
LONG LIFE PUMP procedure has to be started only after checking
PUMP procedure has to be started only after checking
and, if necessary, topping up the pump oil level and lasts 1 hour:
and, if necessary, topping up the pump oil level and lasts 1 hour:
during this time the tool cannot be used.
During the procedure the oil is automatically purified from the
ocedure the oil is automatically purified from the
gaseous
gaseous
polluting
polluting
residues
residues
operations of vehicles air conditioning systems.
operations of vehicles air conditioning systems.
At the end of the LONG LIFE PUMP procedure,
in case of negative result or
after 1000 hours of vacuum pump operation since the last
after 1000 hours of vacuum pump operation since the last
oil change, the LONG LIFE PUMP procedure cannot be
activated anymore
It is necessary to replace the vacuum pump oil.
It is necessary to replace the vacuum pump oil.
| AIR-
-NEX 9380/9480 | 21 en
plers leak, and make the possible
absorbed
absorbed
during
during
the
the
PUMP procedure,
PUMP procedure cannot be
emptying
emptying

Hide quick links: