Siemens AS-i Master CM 1243-2 a Manual page 59

Industrial controls for simatic s7-1200
Table of Contents

Advertisement

Name
Select automatic address enable
(Set_Auto_Addr_Enable)
Write AS-i slave extended ID1
(Write_Extended_ID−Code_1)
Read AS-i line analog input data
(Read_AIDI)
Write AS-i line analog output data
(Write_AODI)
Table 7- 6
AS-i slave calls
Name
Configure parameter value
(Set_Permanent_Parameter)
Read configured parameter value
(Get_Permanent_Parameter)
Write parameter value
(Write_Parameter)
Read parameter value
(Read_Parameter)
Configure configuration data
(Set_Permanent_Configuration)
Read configuration data
(Get_Permanent_Configuration)
Read actual configuration data
(Read_Actual_Configuration)
Read AS-i slave I/O
(Read_I/O_Configuration)
Read AS-i slave ID
(Read_ID−Code)
Read AS-i slave extended ID1
(Read_Extended_ID−Code_1)
Read AS−i slave extended ID2
(Read_Extended_ID−Code_2)
AS-i master CM 1243-2 and AS-i data decoupling unit DCM 1271 for SIMATIC S7-1200
Manual, 04/2013, A5E02655230010A/RS-AA/003
7.2 Description of the AS-i line calls and AS-i slave calls
Function
Index
(decimal)
Write
21
Write
24
Read
25
Write
26
Function
Index
(decimal)
Write
3
Read
4
Write
5
Read
6
Write
8
Read
9
Read
11
Read
33
Read
34
Read
24
Read
35
Using the data record interface
Data in the send or
Description in section:
receive buffer
Mode
"Automatic address programming
(Set_Auto_Addr_Enable)
(Page 76)"
ID1 code
"Write AS-i slave extended ID1
(Write_Extended_ID−Code_1)
(Page 77)"
Analog input data
"Read AS-i line analog input data
(Read_AIDI) (Page 78)"
Analog output data
"Write AS-i line analog output data
(Write_AODI) (Page 80)"
Data in the send or
Description
receive buffer
Parameter value
"Configure parameter value
(Set_Permanent_Parameter)
(Page 81)"
Parameter value
"Read configured parameter value
(Get_Permanent_Parameter)
(Page 82)"
Parameter value
"Write parameter value
(Write_Parameter) (Page 83)"
Parameter value
"Read parameter value
(Read_Parameter) (Page 84)"
Configuration
"Configure configuration data
(Set_Permanent_Configuration)
(Page 84)"
Configuration
"Read configuration data
(Get_Permanent_Configuration)
(Page 85)"
Configuration
"Read actual configuration data
(Read_Actual_Configuration)
(Page 86)"
I/O configuration
"Read AS-i slave I/O
(Read_I/O_Configuration)
(Page 93)"
ID code
"Read AS-i slave ID
(Read_ID−Code) (Page 93)"
ID1 code
"Read AS-i slave extended ID1
(Read_Extended_ID−Code_1)
(Page 94)"
ID2 code
"Read AS−i slave extended ID2
(Read_Extended_ID−Code_2)
(Page 94)"
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-i dcm 1271

Table of Contents