Download Print this page

Grohe EUROSMART COSMOPOLITAN E 36325001 Manual page 12

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
Operating conditions
®
Bluetooth
The current version of the app required for using the system
must be installed on the control unit in advance.
The required App is available for free in the iTunes Store
(requires an Apple account) and the Google Play store
(requires a Google account), see page 1.
For operation under adverse environments, in buildings /
rooms with reinforced concrete walls, steel and iron frame, or
near of obstructions (eg furniture) of metal, the Bluetooth
reception can be disturbed and interrupted.
Type of obstructions
Wood, Synthetic material
Water, Bricks, Marble
Plaster, concrete, glass, solid
wood
Metal
The Bluetooth® adaptor operates in a frequency band of
2.4GHz. The installation near devices with the same frequency
band (eg wireless devices, DECT phones, etc. (observe
manufacturer documentation)) should be avoided.
Technical data
Fitting with switched-mode power supply:
• Voltage supply:
• Power consumption:
Fitting with battery:
• Voltage supply:
®
Bluetooth
:
• Power consumption:
• Output:
®
• Bluetooth
- Transmission distance:
(depending on the environments)
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to
Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape:
12 cm (7 - 20 cm adjustable)
20 cm (7 - 22 cm adjustable)
• Type of fitting protection:
Thermal disinfection possible.
Fault / Cause / Remedy
Fault
Water not flowing
3
Interference or
shielding potential
Low
Medium
High
Very high
100-240 V AC 50-60 Hz/6.75 V DC
6V lithium battery type CR-P2
Bluetooth
20cm
Cause
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Operation and settings,
see technical product information 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
Maintenance
Batteries which are almost discharged are displayed
2.4 W
by a flashing indicator lamp in the sensor system.
Replacement parts
See page 1 (* = special accessories)
Care
1 W
For directions on the care of this fitting, please refer to the
®
- Class 2
accompanying Care Instructions.
about 10m
Disposal note
This category of device does not belong in the domestic
60 s
waste, but must be disposed of separately in
accordance with the relevant national regulations.
1 s
Special accessories - The factory settings can be
12cm
changed and special functions can be activated,
deactivated and set using the infrared remote control
(Prod. no. 36 407). The current Technical Product
Information for the remote control can be downloaded
from www.grohe.com/tpi/remote-control.
IP 59
Remedy
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
11
A
2
2500 V
100 °C

Advertisement

loading