To Install A Safety Harness - Daikin Exigo E1500 Operation Manual

Trailer refrigeration unit
Hide thumbs Also See for Exigo E1500:
Table of Contents

Advertisement

2 General safety precautions
▪ Do NOT touch the refrigerant pipes
during and immediately after
operation as the refrigerant pipes
may be hot or cold, depending on the
condition of the refrigerant flowing
through the refrigerant piping,
compressor, and other refrigerant
cycle parts. Your hands may suffer
burns or frostbite if you touch the
refrigerant pipes. To avoid injury, give
the pipes time to return to normal
temperature or, if you must touch
them, be sure to wear proper gloves.
Electrical
DANGER: RISK OF BURNING/
SCALDING
Allow the evaporator defrost heaters
and the water discharge heater to cool
down before touching them.
DANGER: RISK OF
ELECTROCUTION
▪ Turn OFF all power supply before
removing the switch box cover,
connecting electrical wiring or
touching electrical parts.
▪ Disconnect the power supply for
more than 60 seconds, and measure
the voltage at the terminals of main
circuit capacitors or electrical
components before servicing. The
voltage MUST be less than 50 V DC
before you can touch electrical
components. For the location of the
terminals, see the wiring diagram.
▪ Do NOT touch electrical components
with wet hands.
▪ Do NOT leave the unit unattended
when the service cover is removed.
WARNING
    
Never touch a person receiving an electrical shock, or you
could suffer one too. Do not touch the person until you are
sure power is turned off.
Electrical
shocks
always
attention, even if the victim seems to be fine afterwards.
Operation manual
6
need
emergency
medical
WARNING
▪ After finishing the electrical work, confirm that each
electrical component and terminal inside the electrical
components box is connected securely.
▪ Make sure all covers are closed before starting up the
unit.
Engine
WARNING
Do no operate the unit in road mode
(with diesel engine running) in confined
spaces and areas where fumes from
the engine could become trapped and
cause serious injury or death.
In confined spaces, use the dedicated
function on the HMI to disable
automatic road mode start-up.
WARNING 
Keep your hands, clothing and tools
clear of moving parts such as fans and
engine belt when the unit is working.
DANGER: RISK OF BURNING/
SCALDING
Allow the PM generator, the engine,
the engine exhaust and the engine-
cooling system to cool down before
touching any of these parts.
2.3

To install a safety harness

DANGER
Always use a safety harness with
adjustable sling length and fall damper.
1 Remove one of the grids (a or f). Note: Use an industrial ladder
or another safe platform.
EZESHP20AUAW1B + EZLSHP20AUAW1B