4.2.3

To disable automatic road mode start-up

WARNING
    
When the unit is operating in grid mode and a power
blackout occurs, the automatic road mode start-up function
is activated. This means that the unit will start-up in road
mode.
This function MUST be disabled by the operator when the
cold room is parked in a confined space or an area where
fumes from the engine could become trapped and cause
serious injury or death (e.g. indoor parking, ferry).
1 On any page, press and hold the button (o) next to the
automatic road/grid mode icon (d).
Result: Automatic road mode start-up is OFF.
To change the automatic road mode start-up from OFF to ON:
2 On any page, press (short) the button (o) next to the automatic
road/grid mode icon (d).
Result: Automatic road mode start-up is ON.
4.2.4
To change an operation mode from ON to
OFF
(e.g. thermoregulation)
EZESHP20AUAW1B + EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726855-1 – 2023.03
d
o
Changing the operation mode from OFF to ON is done in the same
manner.
d
o
4.2.5
n
l
k
j
4.2.6
On the Home page:
1 In the home page, press the button (o) next to the
thermoregulation icon (c).
Result: The thermoregulation icon (c) goes to grey.
Result: Thermoregulation mode is set to OFF.
INFORMATION
When the cold room door is closed, a micro switch (NO
contact) sends a signal to the unit.

To set the Set Point

1 Press the "Home page" button (n).
2 Press the "Down" (j) or "Up" (l) button to change the set point.

To select a working mode