About The System; Certification Labels; Components - Daikin Exigo E1500 Operation Manual

Trailer refrigeration unit
Hide thumbs Also See for Exigo E1500:
Table of Contents

Advertisement

b
c
d
a
e
×8
×8
×8
a
Upper right grid
b
Hexagon socket pan head screw
c
Contact washer
d
Retainer washer
e
Top panel
f
Upper left grid
2 Hook the safety harness sling (g) onto one of the two fixing
points (h).
g
h
g
Safety harness sling
h
Fixing point A1
3 Set the adjustable fall damper to 6 kg/Nm.
4 Adjust the length of the sling so the user does not touch the
ground when he falls.
3

About the system

The system consists of a self-contained, diesel/electric powered
thermoregulation (cooling/heating) unit and a complete fuel system.
The unit is designed to be installed by a bodybuilder, on a cold room
trailer for transporting fresh and frozen food.
It is a self-contained, diesel/electric powered thermoregulation
(cooling/heating) unit, mounted on the front wall of the cold room. It
consists of the following main components:
▪ A variable speed engine-generator module powering the unit in
road operation.
▪ Variable speed brushless condenser and evaporator fans.
▪ Two microchannel condenser coils made of long life alloy for
corrosion resistance.
▪ An inverter driven variable speed compressor with vapor injection
and economizer.
▪ A programmable microcontroller developed by Daikin.
▪ Electronic Expansion Valves (EEV).
EZESHP20AUAW1B + EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726855-1 – 2023.03
b
c
d
f
×8
×8
×8
h
▪ Electrical heaters for heating and defrost operations.
▪ A high resolution color HMI, accessible from the outside to control
and command the unit.
▪ A telematics module with IP67 protected box mounted on the front
of the cold room to remotely control and monitor the unit's
parameters and alarms (Daikin by WeMob option).
Furthermore, there is also a complete fuel system that consists of
the following components:
▪ A fuel pre-filter to filter the fuel and remove water from the fuel
before it enters the fuel pump. There is an integrated heater to
warm up the fuel in cold circumstances.
▪ A fuel pump and fuel lines to transport the fuel towards the front of
the cold room and to the unit.
INFORMATION
The sound power level (according to 2000/14/CE) is less
than 96  dBA. It is recommended to wear ear protection
when in the vicinity of the working unit.
3.1

Certification labels

b
a
CE label
b
ATP label
3.2

Components

INFORMATION
The service doors of the unit can only be opened when the
trailer is NOT coupled to the truck, or when the truck and
trailer are at a sharp angle.
INFORMATION
The following figures are examples and may NOT
completely match your system layout.
3 About the system
a
Operation manual
7

Advertisement

Table of Contents
loading

Table of Contents