  • Page 1 Installation manual Exigo E1500 Trailer Refrigeration Unit Installation manual EZESHP20AUAW1B English Exigo E1500 Trailer Refrigeration Unit EZLSHP20AUAW1B...
  • Page 2: Table Of Contents

    ▪ A subset of the latest technical data is available on the regional 6 Preparation Daikin website (publicly accessible). To prepare the cold room ............10 ▪ The full set of latest technical data is available on the Daikin To prepare the unit ..............11 Business Portal (authentication required). 7 Installation ▪...
  • Page 3: For The Installer

    WARNING WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).                Condenser, radiator and evaporator have fins that can WARNING result in injury by cutting/severing or scalding/frostbite. Do not touch these components without adequate protective equipment.
  • Page 4 Diesel is a polluting substance. Any diesel leaking from the CAUTION fuel system may not be released in the environment. Use a door lock system to block the service doors when working inside the service compartment. Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 5: Refrigerant

    The unit is factory charged with refrigerant, no additional charging of Do not remove earth connections while installing the unit. refrigerant is required. Missing earth continuity may lead into electrocution. EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 6: Engine

    Choose the correct saw in function of the wall thickness of the cold room. Make sure the blade is long enough to cut through the entire wall panel. About the box Keep the following in mind: Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 7: Overview: About The Box

    Keep the unit upright in order to avoid damage. ▪ Prepare in advance the path along which you want to bring the unit to its final installation position. EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 8: To Unpack The Installation Kit

    "7.2.3 To install the unit on the cold 1 Bring out the unit that is mounted on the special transport pallet. Use a forklift or a lifting device. Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 9: About The Units And Options

    3 Lift the unit with a lifting device (e.g. overhead crane). User interface Electrical box 4 Remove the plastic film from around the unit. Engine ON/OFF switch Evaporator Radiator Exhaust Fuel pump Fuel pre-filter EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 10: Combining Units And Options

    Solar panel The structural integrity of the trailer/cold room is a Rear door switch responsibility of the user. Daikin accepts no liability for the Fuel level probe Pre-filter heater trailer's or cold room's structural integrity. Cold chain data logger...
  • Page 11: To Prepare The Unit

    4  8]. The size of the holes must fit "4.2 To unpack the installation the chosen option. A typical installation is shown below. EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 12: Installation

    Check that no small parts (e.g. nuts, washers, screws, …) are left inside the unit. Installation Overview: Installation This chapter describes what you have to do and know on-site to install the system. Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 13: To Install The Unit On The Cold Room

    4 Place a washer (e) and lock-nut (f) on each of the 2 bolts (c) accessible through the grid openings, and hand tighten the lock nuts (f). 5 Remove the screw (h) and washer (i) and open the hatch (g). EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 14 The wiring of the controller is connected to the unit. Be careful not to break the wiring while rotating or removing the controller. 9 Open unit's service doors. Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 15: To Install The Top Plate Grids

    Always use a safety harness when working at height. 1 Standing on an industrial ladder (or other safe platform), position the grids (c and d) on the top panel (e). EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 16: About The Drain Hoses

    Keep open sparks and flames away from the battery at all times. 6 Install the brackets (a) together with the relay box (b). 7 Install the nuts (c) and washers (d) on the threaded rods (e). Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 17: Fuel Supply

    Diesel is a polluting substance. Any diesel leaking from the fuel system may not be released in the environment. 7.6.1 To install the fuel tank INFORMATION The fuel tank is not supplied by Daikin. Fuel pre-filter Bolt Flat washer Lock nut...
  • Page 18: To Install The Fuel Pump

    7 Connect the fuel supply line (c) coming from the fuel tank to the adapter (f). 8 Screw the nipple (g) into the diesel pre-filter (d) on the outlet side. 9 Screw the adapter (h) into the nipple (g). Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 19: To Make The Electrical Connections

    Installing the electrical cable is left to the expertise of the trailer. bodybuilder. 20 Attach the fuel line along the trajectory along the undercarriage A typical installation is shown below. of the trailer. EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 20: To Install The Iot Module

    3 Plug the 2 pin connector (c) of the connection cable in the The fuel pump is connected to the X50Y connector. socket (b) of the unit cable. Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 21: To Install The Cold Chain Data Logger

    2 Plug the 2 pin connector of the connection cable in the socket of the unit cable. The cold chain data logger is connected to the X104Y connector. Fuel pre-filter Connector Pre-filter heater EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 22: To Install The Solar Panel

    To avoid injury, give the pipes time to return to normal temperature or, if you must touch them, be sure to wear proper gloves. Installation manual EZESHP20AUAW1B + EZLSHP20AUAW1B Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 23: Hand-Over To The User

    ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). 2 Check the correct functioning (cooling on the evaporator side) ▪ The full set of latest technical data is available on the Daikin of the unit. Business Portal (authentication required).
  • Page 24: Weight

    S*NPL Pressure sensor (low) documentation. Pressure switch (air diff.) Optional equipment Equipment made or approved by Daikin that can be S*PH Pressure switch (high) combined with the product according to the instructions in Transformer the accompanying documentation. Clamp...
  • Page 25 12 Glossary Field supply Equipment NOT made by Daikin that can be combined with product according instructions accompanying documentation. EZESHP20AUAW1B + EZLSHP20AUAW1B Installation manual Exigo E1500 Trailer Refrigeration Unit 4P726857-1 – 2023.03...
  • Page 28 4P726857-1 0000000X 4P726857-1 2023.03 Verantwortung für Energie und Umwelt...