Error Items
When the AUTO OFF lamp is lighted
Monitor display
DRUM ROTA TOO SLOW
DRUM TORQUE ERROR
E-FF
FRONT LOAD ERROR
FRONT LOAD MOTOR
LOADING MOTOR
REEL DIR UNMATCH
REEL TENSION ERROR
SERVO COMM ERROR
SERVO CONTROL ERR
SERVO ERROR
Description
If the cylinder motor speed is abnormally low, the AUTO
OFF lamp lights, and the message display flashes.
When it has been detected that the cylinder motor is
subject to an abnormal torque, the AUTO OFF lamp lights,
and the message display flashes.
If the tape start and tape end are detected simultaneously
either during or after loading, the AUTO OFF lamp lights,
and the message display flashes.
The AUTO OFF lamp lights and the message display
flashes when the take-up reel has been rotating idly for a
fixed period of time while the start/end processing
operation during loading (half position) is being performed.
If the cassette does not move up even when 6 seconds
have elapsed since the VTR was transferred to the eject
mode, the AUTO OFF lamp lights, and the message
display flashes.
<Note>
If the cassette does not move down inside the machine
even when 6 seconds have elapsed since the cassette
was inserted, the VTR is transferred to the eject mode.
When the unloading operation is not completed within 6
seconds, the AUTO OFF lamp lights, and the message
display flashes.
<Note>
When the loading operation is not completed within 6
seconds, the VTR is transferred to the eject (unloading)
mode.
If the reel motor at the take-up side is running in the
reverse direction, the AUTO OFF lamp lights and the
message display flashes.
If an abnormal tension at the supply side is detected in the
reel mode, the AUTO OFF lamp lights, and the message
display flashes.
When the servo microcomputer does not follow the
instructions of the system control microcomputer even
when 10 seconds have elapsed, the AUTO OFF lamp
lights, and the message display flashes.
When there is no response from the servo microcomputer
for 1 or more seconds, the AUTO OFF lamp lights, and the
message display flashes.
When only the servo microcomputer was reset in an
instantaneous power failure, the AUTO OFF lamp lights,
and the message display flashes.
– 31 –
VTR operation
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)
STOP
(POWER OFF 5 ON)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ajde97 - editing system

Table of Contents