K - Gamma Correction
Gamma measures the brightness of midtone values produced by the image. You
can brighten or darken an image using gamma correction. A higher gamma
correction yields an overall brighter image. The lower the setting, the darker the
image. The optimal setting for text images is 50K.
R - Resolution of Signature Capture Area
The resolution is the number of pixels that the scanner outputs per each minimum
bar width. The higher the value for R, the higher the quality of the image, but also
the larger the file size. Values begin at 1000. The scanner automatically inserts a
decimal point between the first and second digit. For example, use 2500 to specify
a resolution of 2.5. Set to zero when using the A and B modifiers (see
Image Width
166
0K
Gamma correction Off (default)
50K
Apply gamma correction for brightening typical document image
nK
Apply gamma correction factor n (n = 1-255)
Example of Gamma
Correction set to 0K:
Example of Gamma Correction
set to 50K:
Example of Gamma Correction
set to 255K:
and
B - Output Image Height
Example of Resolution set to 0R:
Example of Resolution set to 1000R:
Example of Resolution set to 2000R:
on page 164).