natus Bio-Logic AuDX PRO FLEX Quick Start Manual

natus Bio-Logic AuDX PRO FLEX Quick Start Manual

Oae and tympanometry screening
Hide thumbs Also See for Bio-Logic AuDX PRO FLEX:

Advertisement

Quick Links

Bio-logic
AuDX PRO FLEX
®
®
QUICK START GUIDE
OAE and tympanometry
screening

Advertisement

loading

Summary of Contents for natus Bio-Logic AuDX PRO FLEX

  • Page 1 Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE OAE and tympanometry screening...
  • Page 2: Device Connectors

    Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE Device connectors Headphones or On/Off button Power supply USB cable Probe second transducer Label printer Patient response button Air Pump Start menu Please note that not all Start Menu options will be available depending on the configuration and modules on your device.
  • Page 3 Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE Testing: Tympanometry Connect the probe to the red connector and the air cable to the pump connector. From the start menu, select the Immittance: Tymp+Ref button. Select the test ear by pressing either the Right or Left button. Cartoon mode will show an airplane on the screen during the tympanometry test.
  • Page 4 Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE Distortion Product Otoacustic Emissions (DPOAE) Screening Select either the Screening or the Standard button from the start menu and connect the probe to the red connector. Or use the tympanometry probe. Inspect the ear canal, select the appropriate ear tip size and place it on the probe tip.
  • Page 5 Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE Eartip not completely inserted, Eartip squeezed at the end of the Eartip folded on probe tip, space between eartip and probe tip probe tip obstructing delivery of sound Once the eartip is correctly placed in the ear canal, select the test ear by pressing either the Right or Leftbutton. Cartoon mode will start the test showing a cartoon instead of the progress bar.
  • Page 6 Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE A calibration will be performed prior to measurement. A green light indicates successful calibration (see below left). After successful ear probe calibration, the test will start automatically. Progress for each tested frequency Overall test progress Noise floor level Probe fit override for...
  • Page 7 Bio-logic AuDX PRO FLEX ® ® QUICK START GUIDE Detailed results view Red or blue bars indicate response, grey bars indicate Outcome for each test Numeric values shown noise. Press Retest if needed. sorted by f2 and L2 in table format Retest Test other Select frequencies to...
  • Page 8: Copyright Notice

    Internet: www.pathme.de Healthcare solutions with one thing in mind. You. ©2020 Natus Medical Incorporated. All Rights Reserved. All product names appearing on this document are trademarks or registered trademarks owned, licensed to, promoted or distributed by Natus Medical Incorporated, its subsidiaries or affiliates. 7-26-1372-EN Rev01 Natus Medical Incorporated natus.com...