natus Olympic Brainz Monitor Reference Manual

natus Olympic Brainz Monitor Reference Manual

Cfm
Hide thumbs Also See for Olympic Brainz Monitor:
Table of Contents

Advertisement

Reference Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Olympic Brainz Monitor and is the answer not in the manual?

Questions and answers

gemma Cummins
March 6, 2025

Where can we get a replacement measurement tape for siting the probes

Summary of Contents for natus Olympic Brainz Monitor

  • Page 1 Reference Manual...
  • Page 2 © 2019 Natus Medical Incorporated. All rights reserved. This manual may not be reprinted or copied in whole or in part without written consent from Natus Medical Incorporated. The content of this manual may change without notice. Natus Medical Incorporated DBA Excel-Tech Ltd.
  • Page 3: Table Of Contents

    Olympic Brainz Monitor Packaging ........................ 14 Assembling the Roll Stand ..........................14 Attaching and Connecting the Components....................17 PREPARING THE OLYMPIC BRAINZ MONITOR FOR FIRST USE ........... 19 Starting and stopping the Olympic Brainz Monitor ..................19 Setting up the Olympic Brainz Monitor ......................20 Changing the Language ..........................
  • Page 4 Cleaning ................................ 27 Routine Maintenance ............................ 28 Weekly Maintenance............................. 28 Quarterly Maintenance ..........................28 Annual Maintenance ............................. 28 Calibrating the Olympic Brainz Monitor......................29 Upgrading software ............................29 Servicing ................................ 30 SPECIFICATIONS ..........................31 General Specifications ........................... 31 Display................................31 Accessory Basket ............................
  • Page 5: Introduction

    Natus Olympic Brainz Monitor (OBM). For instructions about operating the Olympic Brainz Monitor, applying a neonatal sensor set, and checking for signal quality, see the Quick Start topic in the Olympic Brainz Monitor online Help. Important! It is important that you read the Quick Start section in the Olympic Brainz Monitor Help before you use the neonatal sensor set.
  • Page 6: Essential Performance

    General Safety Information Before using the Olympic Brainz Monitor, read all sections of this manual carefully. Observe all precautions to ensure the safety of the patient and those near the instrument. In addition, please refer to your hospital policy and procedure for EEG administration.
  • Page 7 • Disconnect the Olympic Brainz Monitor from any AC supply outlet before cleaning. Do not use liquid or spray detergents. • Take care to avoid spilling liquid into any opening in any part of the Olympic Brainz Monitor. Do not submerge any component in liquid. This may cause fire or electrical shock.
  • Page 8 • Do not use the Olympic Brainz Monitor in the vicinity of MRI or CT systems. Personal Injury Hazard • Ensure that the touch screen monitor is securely mounted on the roll stand to avoid personal injury. Patient strangulation hazard •...
  • Page 9 Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the OBM Olympic Brainz Monitor , including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
  • Page 10: Symbol Definitions

    • Plug the devices into AC supply outlets on separate circuit branches. Operation of the Olympic Brainz Monitor may be affected by mobile and portable RF communications equipment. Refer to the Olympic Brainz Monitor Technical Manual (027051) for further compliance information and advice relating to electromagnetic interference.
  • Page 11 Product was not ISO 15223- device labels, labelling and Negation symbol made with natural 1 Annex B.2 information to be supplied - rubber latex Part 1: General requirements OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 12 When the equipment comes to the end of its operating life, it should be disposed of in accordance with local waste regulation authority, which is typically within the local government office. OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 13: Terms And Abbreviations

    Terms and Abbreviations The following table describes the terms and abbreviations used on the Olympic Brainz Monitor and its packaging, or in this manual and other documentation. Term or Meaning Abbreviation Amplitude- A time-compression technique for presenting long EEG integrated...
  • Page 14: Olympic Brainz Monitor System Overview

    Olympic Brainz Monitor System Overview The Olympic Brainz Monitor, a Cerebral Function Monitor (CFM), is a three-channel electroencephalograph (EEG) that detects and records small electrical signals from both hemispheres of the patient’s brain. Figure 1: Olympic Brainz Monitor System Touch Screen Monitor...
  • Page 15: Roll Stand

    Printer (recommended: network printer). User Interface Screen The main user interface screen appears when you turn on the Olympic Brainz Monitor. This screen displays the graphs, including aEEG, EEG, and Impedance. For more information about these graphs, see online Help.
  • Page 16: Olympic Brainz Monitor Packaging

    Olympic Brainz Monitor Packaging Depending on final configuration the Olympic Brainz Monitor is supplied in the following separate packages: • A large, narrow box that contains the roll stand components (extendable pole, base with casters, power adapter/cable cleat, accessory basket assembly, and tilt mounting bracket).
  • Page 17 Stage 4: Attaching the AC power and adapter cable cleat Attach the two parts of the power adapter/cable mounting bracket to the extendable pole and tighten the two Phillips screws. See Figure 4 on page 16. OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 18 Tighten the three Phillips screws. See Figure 6 on page 17. Affix the adhesive plastic screw cover to the top of the tilt mounting bracket. Tighten the tilt adjustment lever. OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 19: Attaching And Connecting The Components

    Attach the VESA mounting adapter to the back of the touch screen monitor using the four M4 x 16mm screws. See Figure 7 on page 17. Figure 7: Attaching VESA mounting adapter to the touch screen monitor OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 20 USB ports located under the side panel). • Power adapter to the touch screen monitor. Note: An equipotentiality terminal is provided to optionally connect to a hospital ground/earth system. OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 21: Preparing The Olympic Brainz Monitor For First Use

    (for example DIN VDE 0751 and AS/NZS 3551). Preparing the Olympic Brainz Monitor for First Use This section describes the tasks required to set up the Olympic Brainz Monitor for the first time. See the Olympic Brainz Monitor online Help for more information about configuring the device and changing settings.
  • Page 22: Setting Up The Olympic Brainz Monitor

    24. Setting up the Olympic Brainz Monitor Place the Olympic Brainz Monitor where you are able to see and reach both the touch screen monitor and the patient. Connect the Olympic Brainz Monitor’s power adapter and cable to a suitable AC supply outlet.
  • Page 23: Activating And Configuring Detectors

    USB device or a network share, as well as the folder name that must exist on the USB device or network share. The Olympic Brainz Monitor is preconfigured with one USB location for archiving and one USB location for exporting, as follows:...
  • Page 24: Checking For Normal Operation

    “Configuring locations” under the Tools tab in the online Help. Checking for Normal Operation The Olympic Brainz Monitor performs a system self-check each time it is placed into recording mode. The self-check verifies that the DAB is correctly calibrated. To verify that the Olympic Brainz Monitor is operating correctly, record a short test session and verify that the Olympic Brainz Monitor does not report a system self-check failure.
  • Page 25: Using Olympic Brainz Monitor Components

    Olympic Brainz Monitor unit. Warning! Unlock the casters before moving the Olympic Brainz Monitor unit. • Hold the roll stand handle to push the Olympic Brainz Monitor in front of you, rather than holding the touch screen monitor unit. •...
  • Page 26: Using The Accessory Basket

    A cable cleat is fitted to the lower portion of the roll stand to help manage the AC power cable when the Olympic Brainz Monitor is not in use. To use the cable cleat, loop the cable loosely around the arms of cable cleat. Cables may also be secured and routed using the supplied cable management clamps.
  • Page 27: Using The Online Help System

    The Olympic Brainz Monitor includes an online Help system that describes the major features of the user interface and provides instructions for operating the Olympic Brainz Monitor. It also includes a Quick Start guide that describes the steps involved in an assessment from start to finish.
  • Page 28: System Requirements

    Viewer or OBM Viewer Maintenance, but not both simultaneously) Note: If your Windows firewall is enabled, it will ask you whether or not to allow CfmUIViewer.exe. Answer YES or UNBLOCK in order to correctly use the Viewer. OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 29: Maintenance

    Warning! Use only a soft damp cloth for cleaning. Do not use liquid or spray detergents. Warning! Never pour liquid into any opening in any part of the Olympic Brainz Monitor, or submerge any component in liquid. This may cause fire or electrical shock.
  • Page 30: Routine Maintenance

    Caution: The touch screen monitor and DAB must not be opened except when being serviced by an Authorized Service Center or when following written instructions from Natus Medical Incorporated. The following cleaning instructions apply to the Olympic Brainz Monitor (including the touch screen monitor), DAB, and connecting cables. Normal Cleaning Clean by wiping with a soft cloth dampened with mild detergent and water.
  • Page 31: Calibrating The Olympic Brainz Monitor

    (for example DIN VDE 0751 and AS/NZS 3551). If any component of the Olympic Brainz Monitor is missing or damaged, replace the appropriate part and check the Olympic Brainz Monitor for normal operation before using it again.
  • Page 32: Servicing

    Caution: Follow the instructions supplied with the software upgrade, and then retain the upgrade file in case it is needed again. Caution: Your Olympic Brainz Monitor ships with a Starter Kit. The Starter Kit may include a software update on USB (OBM00462) that is newer than the software installed on your touch screen monitor.
  • Page 33: Specifications

    0-2 Hz: 60 dB/decade 2-12 Hz: 12 dB/decade 12-16 Hz: 1 dB > 10 Hz level 16-30 Hz: -120 dB/decade Computed Parameters • Cross-cerebral and bilateral amplitude-integrated EEG (aEEG) • Impedance OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 34: Display Modes

    -4° F to 140° F (-20°C to 60°C) Shipping Relative Humidity: 25% to 90% non-condensing Shipping Altitude / atmospheric pressure: -1000 feet to +15000 feet (570 hPa to 1060 hPa OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 35: Standards Compliance And Normative References Information

    • Mode of operation: Continuous Regulatory Standards of Compliance and Normative References The Olympic Brainz Monitor and its accessories have been designed to comply with the following national and international standards. Particular Standards: • IEC 60601-2-26 Ed 3.0: 2012 Medical electrical equipment – Part 2-26: Particular requirements for basic safety and essential performance of electroencephalographs •...
  • Page 36: Declaration Of Compliance For Iec 60601-1-2 Edition 4.0

    The Olympic Brainz Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the Olympic Brainz Monitor should assure that it is suitable for use in industrial areas and hospitals except for near active...
  • Page 37 The Olympic Brainz Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the Olympic Brainz Monitor should assure that it is suitable for use in industrial areas and hospitals except for near active...
  • Page 38: Declaration Of Compliance For Fcc

    The Olympic Brainz Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the Olympic Brainz Monitor should assure that it is suitable for use in industrial areas and hospitals except for near active...
  • Page 39: Replacement Parts

    (115 g) Tube (x3) OBM Skin marker, Skin marker for use when applying sensors OBM00044 box of 10 OBM Wrap-hat, bag Cloth head wrap for use with neonatal sensor set. OBM00043 of 10 OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 40: Authorized Service Centers

    Fax: +1-650-802-6620 Natus Medical Technical Service: Email: technical_service@natus.com Telephone: 1-800-303-0306 (US/CAN) Worldwide: +1-650-802-0400 Fax: +1-650-802-8680 Website: www.natus.com Outside U.S Please contact your local Distribution Partner for technical service related issues. OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...
  • Page 41: Appendix A: Assembling The Table Stand

    Figure 11: Attaching the base to the upright post Fasten the stand to the back of the monitor using the 4 screws supplied with the stand. Figure 12: Attaching the stand to the monitor OBM Olympic Brainz Monitor Reference Manual PN 027050 Rev 05...

Table of Contents

Save PDF