Accessories; Technical Data - Hilti PRM 15 Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
2.5 Indication while receiving
Charging status indicator
Pre-set level indicator
en
Plumb indication
2.6 LED indication after connecting the AC adapter
Battery charge status display

3 Accessories

Designation
PRA 86 car charging connector

4 Technical data

Right of technical changes reserved.
PRM 15 machine receiver
Laser reception angle
Sensor reception measurement
Vertical reception
Machine receiver range (radius)
Machine receiver accuracy
Laser rotation speed range
Receiver compatibility
Unaffected by light pulses from warning lights on con-
struction sites
12
Battery fully charged: LED is off.
Low battery: The red LED blinks.
Battery exhausted: The red LED lights until the battery is completely dis-
charged.
The height of the receiver in relation to the height of the laser beam is
indicated by the bright red LEDs which, at the same time, indicate the
direction in which the receiver has to be moved in order to bring it to the
pre-set level.
When the bright green LED lights, this indicates that the receiver is at the
pre-set level of the rotating laser.
The receiver is plumb: The pre-set level indicators light constantly.
The receiver is not plumb (±2.5 degrees off plumb): The pre-set level
LEDs blink rapidly or slowly.
Battery conditioning phase: This phase prepares the battery for the nor-
mal charging phase. This phase begins as soon as the cord is plugged in
to the electric supply and lasts for approx. 10-20 minutes.
- The green LED blinks slowly (0.85 Hz) - the conditioning phase is act-
ive.
- The green LED blinks rapidly (1.7 Hz) - error during the conditioning
phase.
Normal charging: This phase begins after successful completion of the
conditioning phase.
- The green LED lights constantly - the battery is being charged.
- The green LED blinks slowly and regularly (0.85 Hz) - the battery is fully
charged.
- The green LED blinks very rapidly (6.7 Hz) - error during charging. The
charging cycle has been aborted. Disconnect the AC adapter and then
reconnect it or, alternatively, replace the battery.
2 x 180° = 360°
Continuous proportional
203 mm (8 in)
3...488 m (10 ft to 1600 ft)
±2 mm (±0.079 in)
150 /min to 1200 /min
Standard infrared and visible rotating lasers
Yes

Advertisement

Table of Contents
loading

Table of Contents