9. Electrical wiring

The installation of the Heatflow S5 requires a power outlet (120V). The wiring must be done in
accordance with the local legislation/norms and with the national building code.
The wiring must be done by a certified electrician only.
The Heatflow S5 must be wired on a 120V circuit, 15 amps.
WARNING: Special attention must be taken to the passage of wires and should be shielded from
radiation. WIRES SHOULD NEVER BE IN CONTACT WITH ANY PART OF THE SYSTEM (Stove,
Heatflow S5 jacket, air conduit, pipe, etc ...)
Connect the blower to the control sub-assembly (G) with a 14/2 wire and wire splices. The following
schematic shows how:
Installation Instruction HEATFLOW S5
WARNING
English
17
46310A
2023-03-15