Note: Next image as an indicative reference only of a typical 3 air outlets system
11.
Operating instructions
NEVER BLOCK ANY HOLES/LOUVERS ON THE HEATFLOW S5 METAL JACKET. FAILURE TO
DO SO COULD RESULT IN FIRE, INJURY, DAMAGE TO THE STOVE, BLOWER OR AIR
DUCTWORK SYSTEM, etc..
DO NOT MODIFY THE SYSTEM. FAILURE TO DO SO COULD RESULT IN FIRE, INJURY,
DAMAGE TO THE STOVE, BLOWER OR AIR DUCTWORK SYSTEM, etc..
Always put the system to "OFF" while reloading the stove with wood.
IMPORTANT : If the stove is new, it is normal to have an odor of smoke when lighting it for
the first time. This intitial fire should always be done before connecting the air ductwork
system to the HEATFLOW S5 in order to prevent the odor of smoke being dispersed to
all rooms.
1. Plug the control sub-assembly into an electrical outlet.
2. Select the desired mode with the 3 position switch located on the top of the control box behind the
HEATFLOW S5.
A- « AUTO MODE » in this position, the blower will
start and stop automatically with the temperature of
the stove.
O- « OFF MODE » in this position, the blower is
stopped immediately. It is recommended to put the
system in this mode when reloading the stove
with wood.
M- « MANUAL MODE » in this position, the blower
will always be energized.
3. Adjust the blower speed with the rheostat to optimise comfort at air outlet
a. Higher blower speed  Lower temperature at air outlet
b. Lower blower speed  Higher temperature at air outlet