Summary of Contents for Lincoln 85418

  • Page 3 Model Specification Operating Solenoid Valve Heater Model Voltage Initial Current Current 85418 115 VAC .18 Amps 1.80 Amps...
  • Page 11 Service Parts Item Item Qty. Description Part No. Qty. Description Part No. 10-32 x 1/2 Tapping Screw 270871 30 Piston 252764 Enclosure Cover Ass’y (Includes Item 3) 271387 31 Pipe Plug (1/8 NPT) 68645 Enclosure Gasket 271570 32 Check Valve 130021-3 Bulkhead Adapter 271564 33...
  • Page 12: Troubleshooting

    Troubleshooting Symptom Possible Cause Remedy Airless spray system No electrical power Turn on power. will not dispense Clogged spray tip. Clear clogged tip. lubricant Pump out of lubricant. Fill reservoir. Pump failure. Repair pump. Defective solenoid spray valve. Repair or replace solenoid valve. Defective pressure switch.