Page 1
User and maintenance instructions Centro-Matic Models , MSO, and MSO MSO model shown Date of issue October Form number Version ...
Page 2
Contents Declaration of Incorporation* .. U.K. Declaration of Incorporation* . . . Safety* .........
Page 3
Pneumatic fluid power. General rules and safety requirements for systems and their Components I, the undersigned of Lincoln Industrial Corporation, do hereby declare that the equipment specified above, in its intended use, conforms to the requirements of the above EC Directive(s). ___________________________________...
Page 4
Proceedure for hydrostatic testing I, the undersigned of Lincoln Industrial Corporation, hereby declare that the equipment specified above, in its intended use, conforms with the Essential Health and Safety Requirements of U.K. legislation Supply of Machinery (Safety) Regulations No. Annex I, Declaration of Incorporation by the time of placing it on the market.
Safety* Explanation of signal WARNING words for safety Do not allow any body part to be trapped by equipment. The assembly must be installed, maintained Body parts can be crushed and repaired exclusively by persons familiar by subassemblies during with the instructions.
Usage Description Appropriate use Operation with system controller Models , MSO, and • Pumps on these units are exclusively MSO are pumping units designed to designed to pump and dispense lubricants operate centralized lubrication systems with using compressed air only. When system controller times out, lube cycle a high volume output, delivering •...
Page 7
Fig. Dimensions, model MSO shown ∅ 15 in (381 mm) ∅ 13.9 in (353 mm) 19 in ∅ 0.50 in (13 mm) (483 mm) 40° 20° 31 in (787 mm) ...
Installation and operation Installation Operation Fill reservoir (MSO equipped) Place unit in approximate location making sure grease and air connections are Body and guide assembly (), pivot arm accessible. (), supply line relief, follower () and NOTE cover () work in combination with each Do not overfill reservoir.
Maintenance and repair General maintenance Outlet check service Remove outlet connector () from bushing (). • Keep area around pump clean. Clean off Refer to Troubleshooting (page ) to Remove ball check seat () from outlet filling area prior to filling reservoir. Clean determine if outlet check valve () is connector ().
Page 10
Follower For follower without foam For follower with foam (models (model ) MSO and MSO) If follower wiper appears to be damaged or does not wipe sides of container effectively, Refer to Fig. IPB (page ) and Fig. Refer to Fig.
Page 11
Fig. Follower assembly (on models MSO and MSO) ) Stagger long bolts and small bolts on follower plate. ...
Vent valve service Low level indicator Fig. Vent valve assembly () Refer to Troubleshooting (page ) to If indicator pin appears to drop prematurely determine if vent valve is cause of failure or water is noticeable on top of follower then (†...
Page 13
Safety unloader valve Automatic mechanical shut-off Safety unloader () († Fig. IPB , page ) is set to open at to psi ( to bar) lubricant pressure. If Refer to manual for automatic pressure switch fails to operate and shut off mechanical shut-off.
Page 14
Fig. IPB Service parts (model ) ...
Page 15
Fig. IPB Service parts (model MSO) ...
Page 16
Fig. IPB Service parts (model ) ...
Page 17
Fig. IPB Service parts (model MSO) ...
Troubleshooting Condition Possible cause Corrective action Pump does not operate. No air to pump. Turn on or connect air supply to pump. Air motor or pump tube malfunction. Refer to pump manual . Air seepage from air exhaust while Air motor malfunction. Refer to pump manual .
Need help?
Do you have a question about the SKF Centro-Matic and is the answer not in the manual?
Questions and answers