Power Supply Unit - tams elektronik B-6 Manual

Booster for digital model railway layouts
Table of Contents

Advertisement

tams elektronik

9.2. Power supply unit

Manufacturer
Type designation
Output
Output voltage
Rated current
Output current
Rated powerNennleistung
Input
Input voltage
Frequency range
Input current
Efficiency
Power consumption
at zero load
Protection
Protection type
Protection class
Overload
Overvoltage
Overtemperature
MEAN WELL ENTERPRISE Co. Ltd.
GSM160B24-R7B
24 VDC
6.67 A
0 – 6.67 A
max. 160 watts
80 ~ 264 VAC or 113 ~ 370 VDC
47 ~ 63Hz
90A / 115VAC or 110A / 230VAC
average: 93,5 %
at low load (10%): 87.5 %
< 0,15 W
IP 22
Meaning: Predected against solid foreign bodies with diameter ≥ 12.5 mm and
access with a finger. Protection against falling dripping water when the
enclosure is tilted up to 15°.
(= Protection class 2)
105 ~ 150% of the rated output power
Protection mode: Hiccup mode, i.e. automatic recovery after
elimination of fault condition
105 ~ 135% of the rated output voltage
Protection mode: Switching off the output voltage, switching
on again for recovery
Protection mode: Switching off the output voltage, switching
on again for recovery
Booster B-6