Message Enumerations
NO_PRIORITY
NO_SERVICE
NO_SITE
NO_UKEKS
NUM_CHNL_FAIL
OUT_OF_RANGE
PARMS_FAILED
RECEIVE_ONLY
REGISTRATION_DENY
REGISTRATION_FAILED
REGISTRATION_REFUSED
REKEY_FAIL
RESPONSE_ONLY
Draft 02 - Sep 1 2015
Viking Mobile Radio Operating Manual
Portable/SCH/LCH
Strings
Description
"No Priorty"
This error occurs when attempting to use the conventional
Priority feature on a non-priority scan list.
"NO PRIORTY"
"No Priorty"
"No Service"
This error indicates that OTAR service is not available.
"NO SERVICE"
"No Service"
"No Site"
This error indicates that no site with a verified ID is yet on the
dynamic site list. This applies to the Site Lock feature.
"NO SITE"
"No Site"
"No UKEK"
This error occurs when attempting to rekey with no UKEK.
"NO UKEK"
"No UKEK"
"Channl Limit"
If seen upon startup, this error indicates that the radio has
been programmed with more channels than what it is
"CHANL LIMT"
optioned for. This error is also indicated with 10 orange blinks
"Channel Limit"
of the LED.
"Out Of Range"
This error indicates no control channel has been found for
trunking operation.
"OUT OF RNG"
"Out Of Range"
"Parms Fail"
There is no parameter file in the radio. This error will also be
indicated with 3 orange blinks of the LED.
"PARMS FAIL"
"Parms Fail"
"Rx Only"
This error indicates that the selected channel is Rx only. This
can occur if transmit disabled is selected or a conventional
"RX ONLY"
channel is configured with talkgroup 0.
"Receive Only"
"Reg Deny"
This error indicates that a unit registration attempt has
received a DENY response from the system. The precise
"REG DENY"
reason for a DENY response is manufacturer dependent. One
"Reg Deny"
common cause is that the unit ID is disallowed on the site/
RFSS that the radio is attempting to register on.
"Reg Failed"
This error indicates that a unit registration attempt has
received a FAILED response from the system. The precise
"REG FAILED"
reason for a FAILED response is manufacturer dependent.
"Reg Failed"
"Reg Refused"
This error indicates that a unit registration attempt has
received a REFUSED response from the system. The precise
"REG REFUSD"
reason for a REFUSED response is manufacturer dependent.
"Reg Refused"
"Rekey Failed"
This error indicates a failure in a rekeying process.
"REKEY FAIL"
"Rekey Failed"
"Resp Only"
This error indicates that the Unit Call/Call Alert setting to set to
Response Only.
"RSPNS ONLY"
"Response Only"
Tones & Error Messages
9-7