1 General Information
Passive infrared detector «Foton-SH1» (hereinafter, the Detector)
is designed for detecting intrusion into the protected closed area
of a room through door and window openings, for generating and
transmitting alarm messages by current step-up in an alarm loop
(hereinafter, AL).
2 Features
- Dual-element pyrodetector.
- «Vertical curtain» detection zone.
- Recommended installation height is not lower than 2.5 m.
- Adjustment mode choosing.
- Possibility of LED indication disabling.
- Detection zone alignment ability.
- Is rated for connection to AL with operating voltage DС 8 ... 30 V.
- Connection up to 4 detectors to AL.
- High resistance to ambient light – up to 12 000 lx.
- Immunity to small pet's movement.
- Compact, attractive design.
- Ease of installation and servicing.
- Wall installation by means of the swivel bracket (supplied).
3 Choosing an Installation Place for the Detector
The Detector is designed for using in closed premises (shops,
offices, museums, flats, etc). When choosing place of the Detector
installation, it is advisable to take note of the fact that the detection
zone may be limited by non-transparent objects (curtains, curtain
holders, door trims, etc), as well as glass partitions. There must be no
air conditioners, space heaters or heating radiators in the Detectors'
detection zone. Maximum installation height of the Detector is 5 m.
Alarm loop wiring should be conveyed far enough from high-energy
electrical power cables.
4 Jumpers Setting and LED Indication Modes
Set the Detector jumpers corresponding to the specified application
conditions.
Table 1
Characteristic
Jumper
Sensitivity
«PULSE»
Alarm LED
«IND»
indication
5 Specifications
Table 2
Parameter
Installation height, up to
Warm-up time, not more than
Alarm message duration, not less than
Voltage supply (AL)
Consumption current:
- in standby mode, not more than
- in Alarm mode, adjustable in the limits
Operating temperature
Relative humidity at 25
0
С, up to
Sensitivity, chosen by jumper «PULSE»
installation
Detection zone
Dimensions
Weight
PASSIVE INFRARED
DETECTOR
«FOTON-SH1»
Installation Guide
Mode in case
Mode in case
jumper is
jumper is
installed
removed
«1» – high
«2» – normal
LED Indication
LED Indication
disabled
is in operation
Value
5 m
60 sec
2 sec
8 ... 30 V
0.3 mА
1.0 ... 3.2 mА at UAL min = 8 V
2.6 ...13.2 mА at UAL max = 30 V
minus 30....+50
95 %
High/Normal
Vertical curtain
91 х 52 х 56 mm
120 g
6 Scope of Delivery
Each Detector unit package contains items listed in Table 3.
Table 3
Passive infrared detector «Foton-SH1»
Swivel bracket
Tap screw 3х10.01.016
Screw nail 3-3х30.016
Passive infrared detector «Foton-SH1». Installation Guide
7 Detection zone pattern
a)
8 Quantity of the Detectors Connected to one Alarm
Loop
8.1 Connection patterns are shown in Figure 6.
8.2 Quantity of the detectors connected to one AL can be defined
by the following formula:
I
0
n =
I
9 Installing the Detector
ATTENTION! During the Detector mounting be careful with the
optical filter located on pyrodetector.
9.1 Insert a flat screwdriver into the clip slit trench in the lower part
of the Detector case and depress the clip (See Figure 2).
9.2 Loosen the screws, providing fixation of the base and remove it
from the swivel bracket (Figure 3).
9.3 Remove port plugs for wire installation at the swivel bracket. Run
the wires through the swivel bracket openings and fasten the swivel
bracket at the chosen place on the wall (See Figure 4).
–
9.4 Install the base with the printed circuit board (PCB) on the swivel
bracket at such a distance from the wall, where curtain-rods would
not shut in the detection zone.
Fix the base on the swivel bracket by means of tap screws (See
Figure 3).
С
0
Name
b)
Figure 1
I
– AL current level, at which AL load voltage value
8
0
is equal to 8 V;
R
I
– current applied to the Detector with installed
term
1
terminal resistor, providing AL alarm state;
1
R
– resistance of the terminal (EOL) resistor.
term
Figure 2
Figure 4
Slots in the Lens
Figure 5
QNT
1 pc.
1 pc.
2 pcs.
2 pcs.
1 copy
5 m
6.8 m
Figure 3
Wires
Openings for
wiring
180
0
Need help?
Do you have a question about the FOTON-SH1 and is the answer not in the manual?
Questions and answers