Rielta FOTON-17 Installation Manual

Passive infrared detector

Advertisement

Quick Links

Installation Guide

General Information

Passive infrared detector «Foton-17» (hereinafter, the Detector) is intended
for detecting intrusion into a closed protected space and generating an alarm
message. The Detector provides additional confirmation response of intruder
detection via TV channel.
The Detector provides case tamper protection by means of microswitch
contacts opening.
The Detector has immunity to impacts of ambient light, radio interference and
small animals movement.
The Detector is easy in installation and servicing. Possible ways of installation
are: wall and corner mounting in ordinary way, or wall and ceiling mounting by
means of the swivel bracket.

Features

-
Sensing element – dual-element pyrodetector.
- Spherical lens.
- Protection against ingress of insects to pyrodetector.
- Microprocessor-based signal processing.
- TV-camera has two operation modes:
- starts operation when alarm message is generated;
- operates continuously.
It is recommended to choose continuous operation mode of TV cameras for
detection zone alignment.
When camera is on, LED indicator is periodically blinking green at a frequency
0.5 Hz.
The Detector provides possibility of the following parameters choosing:
- sensitivity leve;
- LED indication mode;
- period of TV-camera operation.
- The Detector ensures self-test mode.
- The Detector generates failure message when ambient temperature exceeds
+46 °С.
- The Detector is powered by DС power supply with output voltage (10 ... 15) V.
- Swivel bracket for the detection zone alignment is included in the scope of
delivery.

Specifications

Table 1
Parameter
Detection zone
Power supply, DC
Output relay contacts
Alarm message duration
TV signal duration after alarm message
generation
Detection zones
Sensitivity
TV-camera
Operating temperature
Relative humidity without moisture
condensation at a temperature+25
С
0
Dimensions
Weight, not more than
Detection zone pattern is shown in Figure 1.
Figure 1 – Detection Zone Pattern

Scope of Delivery

Each Detector unit package contains the items listed in Table 2.
PASSIVE INFRARED
DETECTOR
«FOTON-17»
Value
12 m х 10 m
10.0 ... 15.0 V, current 150 mА
closed – «Norm» message,
current 30 mА, voltage 72 V
not less than 2 sec
is set by DIP-switches
«4» & «5»
10 long-range zones, 6 middle-range zones,
3 short-range zones, 2 anti-sabotage zones
is selected by DIP-switch «1»
black-and-white video signal;
detection angle in horizontal plane 90°
TV camera resolution 350 TVL
minus 30
0
С ... +50
0
С
95 %
126 х 80 х 60 mm
200 g
12 m
12 m
Table 2
Name
Passive infrared detector «Foton-17»
Swivel bracket
Screw 1-3х20.016
Passive infrared detector «Foton-17». Installation guide

Field of Application

The Detector is used as a component of alarm equipment complexes.

Choosing Place of Installation

The Detector is intended for operation in closed non-heated premises with
lighting in the protected room not less than 15 lx.
Choosing place of installation one should pay attention to the fact, that the
detection zone should not be limited by non-transparent objects (curtains,
houseplants, cabinets, bookcases, etc.), which can create «dead zones»,
preventing the intruder detection. Also there must be no windows, air conditioners,
space heaters or heating radiators as well as incandescent lamps near the
Detector.
The Detector should be installed at 2.3 m height. If the Detector is mounted
on the swivel bracket, the installation height is 2.3 ... 3 m. In this case align the
detection zone position and check receiving TV camera image of the protected
area.
Power supply and alarm loops should be wired far enough from power supply
cables.

Installation

- Unfasten the latch through the opening, which is situated downside the
Detector case by means of screwdriver and put off the Detector cover (Figure 2).
- Put off the PCB by means of pushing up it's fixing arm.
- Drill the holes in the base of the Detector for wiring and fastening the Detector
(Figure 2).
Swivel bracket Components
Plug
Sphere
Screw
Swivel bracket
Swivel bracket wall
mounting
Swivel bracket ceiling
mounting
For wall
mounting
Figure 2 – The Detector Base and the Swivel Bracket
- Choose the place of installation, mark the places for mounting holes with the
regard to Detector base (or swivel bracket) openings, drill the holes in the wall.
- Pass the wire through the mounting holes in the base, leave several
centimeters of installation wire for it's fastening inside the case.
- Fix the base of the Detector case (swivel bracket) at the chosen place. In case
of swivel bracket using, unscrew the cap screw from the swivel bracket sphere.
Fit the square bulge of the swivel bracket external sphere with the corresponded
opening on the Detector base. Plug in the screw to the opening in the top of the
Detector base and fix the connection by the screw.

Connection

- The terminals for the Detector connection are located at the top of PCB.
- Fulfill connections in accordance with the Figure 3a (for single alarm loop
connection) and with Figure 3b (with alarm loop and tamper connection).
- Install the DIP-switches «1», «2», «3», «4» and «5» in accordance with
application conditions.
- Put the Detector cover on it's place.
Detector
Circuit
Cont.
To power
1
+12V
supply
2
-12V
3
AL
4
AL
To CP
5
TAMPER
R
6
TAMPER
term1
7
VIDEO
8
GND
a)
Base
For fastening base to
swivel bracket
For corner
mounting
Openings
for wiring
Opening for
cover latch
PCB fixing arm
Detector
Cont.
Circuit
+12V
1
-12V
2
AL
3
R
AL
4
term1
TAMPER
5
R
TAMPER
6
term1
7
VIDEO
8
GND
b)
Figure 3
QNT
1 pc.
1 pc.
2 pcs.
1 copy
To power
supply
Security
AL
Tamper
AL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FOTON-17 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rielta FOTON-17

  • Page 1 The Detector is used as a component of alarm equipment complexes. General Information Choosing Place of Installation Passive infrared detector «Foton-17» (hereinafter, the Detector) is intended The Detector is intended for operation in closed non-heated premises with for detecting intrusion into a closed protected space and generating an alarm lighting in the protected room not less than 15 lx.
  • Page 2 (the distance, which is possible to pass through the detection and classified as fit for operation and packed by «RIELTA» JSC. zone up to the point, where the movement is detected, and alarm message is generated).

Table of Contents