16.3
North American J-215 and J-225 Convertible Power Models
(For a 4-wire 240V 60 Hz connection)
This wiring diagram is used for all North American 240V 60 Hz
convertible power models. Dedicated 240V models must be permanently
connected (hard-wired) to the power supply.
Note: 240 VAC 4-wire connection enhances heater output from 1kW to
4kW.
1. TB1 MUST BE WIRED WHT-1, BLK-2, RED-3
2. REMOVE JUMPER WIRE BETWEEN J4 AND J20. FAILURE TO DO SO WILL
RESULT IN DAMAGE TO THE PWA.
3. MOVE J46 WIRE FROM AREA 3 TO AREA 1
4. CHANGE F3 FUSE TO 0.1A SLO-BLOW
5. REMOVE 1 JUMPER FROM J24, PLACE REMAINING JUMPER ON PINS 2 AND 3.
6. PUT J31 JUMPER ON 2 PINS
WHT
BLK
RED
GRN
F3 FUSE MUST BE
REPLACED BY A 0.1A
SLO-BLOW FUSE
(SUPPLIED WITH PACK)
J31 JUMPER MUST BE
ON 2 PINS WHEN
HEATER IS CONFIGURED
J31
AS 240VAC
TB1
1
1
2
2
J10
3
240V
J24 JUMPERS MUST BE IN
240V POSITION AS SHOWN
120V 120V
ON
OFF
3
2
J51
J52
3
SWITCH #2
SET TO ON WHEN
HEATER IS
CONFIGURED
AS 240VAC