Download Print this page

HMS Networks Anybus Wireless Bolt II Quick Start Manual

Hide thumbs Also See for Anybus Wireless Bolt II:

Advertisement

Quick Links

Safety and Compliance Information
For Information in Other Languages
English: To download a language version of this Safety and Compliance
Information: 1. Find the product article number on the product cover. 2.
Scan the QR code to access www.anybus.com/support. 3. Enter the product
article number to search for the product specific support web page.
Deutsch: Zum Herunterladen einer Sprachversion dieser Sicherheits-
und Konformitätsinformationen: 1. Suchen Sie die Artikelnummer des
Produkts auf der Produktabdeckung. 2. Scannen Sie den QR-Code, um
auf
www.anybus.com/support
zuzugreifen. 3. Geben Sie die Artikelnummer
des Produkts ein, um die produktspezifische Support-Webseite zu suchen.
Español: Para descargar una versión de esta información de seguridad y
cumplimiento en un idioma concreto: 1. Busque el número de artículo
del producto en la portada del producto. 2. Escanee el código QR para
acceder a www.anybus.com/support. 3. Introduzca el número de artículo del
producto para buscar la página web de soporte específica del producto.
Français: Pour télécharger une version linguistique de ces informations
sur la sécurité et la conformité : 1. Trouvez le numéro d'article du
produit sur le couvercle du produit. 2. Scannez le code QR pour accéder
à www.anybus.com/support. 3. Saisissez le numéro d'article du produit pour
rechercher la page Web d'assistance spécifique au produit.
Italiano: Per scaricare una versione di queste informazioni sulla sicurezza
e sulla conformità nella tua lingua: 1. Trova il numero di serie del
prodotto sulla confezione. 2. Scansiona il codice QR per accedere
www.anybus.com/support. 3. Inserisci il numero di serie del prodotto per
cercare la pagina web di supporto dedicata al prodotto.
日本語: この「安全およびコンプライアンス情報」の各言語バージョ
ンをダウンロードするには:1.製品のカバーにある製品番号を確認し
ます。2.QR コードをスキャンして
www.anybus.com/support
スします。3.製品番号を入力して、その製品に関するサポートウェブ
ページを検索します。
Svenska: Så laddar du ner en språkversion av denna information
om säkerhet och regelefterlevnad: 1. Leta rätt på produktens
artikelnummer på produktens hölje. 2. Skanna QR-koden för att
öppna www.anybus.com/support. 3. Ange produktens artikelnummer för att
söka efter den produktspecifika supportwebbsidan.
© 2023 HMS Networks
Box 4126, 300 04 Halmstad, Sweden
SP3091 / Publication date 2023-03-20
Warning Levels
WARNING
Instruction that must be followed to avoid a risk of
death or serious injury.
CAUTION
Instruction that must be followed to avoid a risk of
personal injury.
General Safety
CAUTION
This equipment emits RF energy in the ISM
(Industrial, Scientific, Medical) band. Make sure
that all medical devices used in proximity to
this equipment meet appropriate susceptibility
specifications for this type of RF energy.
CAUTION
This equipment contains parts that can be
damaged by electrostatic discharge (ESD). Use ESD
prevention measures to avoid damage.
CAUTION
If this equipment is used in a manner not specified
by the manufacturer, the protection provided by the
equipment may be impaired.
CAUTION
Connecting power with reverse polarity or using
the wrong type of power supply may damage the
equipment. Make sure that the power supply is
connected correctly and of the recommended type.
CAUTION
This equipment is not intended for use in an
environment where children are present. Keep out of
reach of children.
にアクセ
Intended Use
The intended use of this equipment is as a communication interface and
gateway. The equipment receives and transmits data on various physical and
wireless levels and connection types.
®
Anybus
Wireless Bolt II
Model Identification
Hardware description
Model identification
Functionality: Ethernet
AWB6BA
Interface configuration: RJ45 and 3-pin power socket
Installation
• Mount the Bolt II (1) on a machine or cabinet.
• Mounting hole diameter: M50 (50,5 mm)
• Ensure to use the included sealing (2) ring and lock nut (3).
• Bolt II lock nut (3) tightening torque: 5 Nm ±10 %
• The top mounting surface, in contact with the sealing, must be:
• flat with a finish equivalent to Ra 3.2 or finer.
• cleaned and free from oils and greases.
2
• Use 0.25 - 1.5 mm
(24-16 AWG) cable for supply wiring.
• If the Ethernet cables are to be exposed in an outdoor environment,
transient protection must be provided.
• Use minimum 90 °C copper (Cu) wire only.
• Use in Overvoltage Category II Pollution Degree 2 Environment
conforming to EN 60664-1.
• This equipment is designed to comply as Class III equipment according to
61010-2-201.
- Safety and Compliance Information
Connectors
Power Connector 3-Pin
Pin
1
+
Recommended: 12–24 VDC Reverse voltage protection
Min: 10 VDC
2
-
Max: 33 VDC
3
Functional Earth (FE)
Ethernet Connector RJ45 PoE
Pin
Data
PoE
Pin
Data
1
TD+
A+
5
N/A
2
TD-
A+
6
RD-
3
RD+
A-
7
N/A
4
N/A
B+
8
N/A
Shield
For Use in North America and/or Canada
The unit shall be supplied by an isolated power source which fulfils the
requirements of Limited-Energy Circuit in accordance with UL/CSA 61010-1/
UL/CSA 61010-2-201 or Limited Power Source (LPS) in accordance with
UL/CSA 60950-1 or a Class 2 supply source which complies with the National
Electrical Code (NEC), NFPA 70, Clause 725.121 and Canadian Electrical Code
(CEC), Part I, C22.1.
For Use in Europe
The unit shall be supplied by LPS Power Source in accordance with the IEC
62368-1.
PoE
B+
A-
B-
B-

Advertisement

loading

Summary of Contents for HMS Networks Anybus Wireless Bolt II

  • Page 1 1. Leta rätt på produktens artikelnummer på produktens hölje. 2. Skanna QR-koden för att öppna www.anybus.com/support. 3. Ange produktens artikelnummer för att söka efter den produktspecifika supportwebbsidan. © 2023 HMS Networks Box 4126, 300 04 Halmstad, Sweden SP3091 / Publication date 2023-03-20...