NOTE
Save these orifices and note their positions for future conversions back to natural gas.
3. Locate the LP conversion orifices that were shipped with the cooktop.
4. Identify the proper orifice by orifice size for each of the cooktop burners.
5. Install the proper orifices in each of the burner cups and tighten with a
nut driver.
NOTE
Any other placement of orifices could result in dangerous operating conditions and/or
poor cooking results.
6. Set all burner heads on top of the burner bases or burner cups in the same location as
they were removed. The hole on the side of the burner heads goes over the electrodes.
The burner heads are correctly installed when they are flat on the top of the burner
bases or burner cups.
7. Set all burner caps on top of the burner heads. These are also flat when they are
installed to ensure proper safe operation.

Adjusting low flame setting on cooktop burners

Check all burner flames at their lowest setting. Use these steps to check and adjust the
burner settings.
NOTE
• Low-setting adjustments should always be made with two or more burners operating
simultaneously.
• Call for service when you need to adjust the inner flame of the cooktop center burner
settings.
1. Turn on two or more cooktop burners and set them between MED and HI.
2. Quickly turn one of the control knobs counterclockwise to the lowest setting. (The
flame should stay lit. If it goes out, adjust the bypass valve on that burner's control
valve.
3. Pull the control knob for that burner straight off.