Adjusting Low Flame Setting On Cooktop Burners - Dacor DTG36M955F Installation Instructions Manual

Modernist gas cooktop
Hide thumbs Also See for DTG36M955F:
Table of Contents

Advertisement

NOTE
Save these orifices and note their positions for future conversions back to natural gas.
3. Locate the LP conversion orifices that were shipped with the cooktop.
4. Identify the proper orifice by orifice size for each of the cooktop burners.
5. Install the proper orifice in each burner cup, and tighten with a
NOTE
Wrongly located orifices could result in dangerous operating conditions and poor
cooking results.
6. Set all burner heads on the same burner bases and cups from which they were
removed. The hole on the side of the burner heads goes over the electrodes. The
heads are correctly installed when they lie flat atop the bases or cups.
7. Set all burner caps atop the burner heads. These also lie flat when installed, ensuring
proper safe operation.

Adjusting low flame setting on cooktop burners

Check all burner flames at their lowest setting. Use these steps to check and adjust the
settings.
NOTE
Low-setting adjustments should always be made with two or more burners on at once.
Call for service when you need to adjust the inner flame of the center burner settings.
1. Turn on two or more cooktop burners, and set them between MED and HI.
2. Quickly turn one of the control knobs counterclockwise to the lowest setting. (If
the flame goes out, adjust the bypass valve on that burner's control valve.
3. Pull the control knob for that burner straight off.
34
English
/
" or 7 mm nut driver.
9
32