Intermittent Pilot Lighting Instructions - Empire Comfort Systems DVCT30CBN95N-2 Installation Instructions Manual

Fireplace heater
Table of Contents

Advertisement

INTERMITTENT PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot
by hand, use the remote control. Before lighting the pilot,
ensure that the master switch is on. When lighting the pilot,
follow these instructions exactly.
B. Before lighting smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas
Do not try to light any appliance.
Do not touch any electrical switch;
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
1.
STOP! Read the safety information above.
2.
Turn OFF electric power to the appliance.
3.
Remove front surround panel assembly or bottom louver if
included.
4.
Turn gas shut-off valve counterclockwise
position.
5.
Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow
in the safety information above on this page. If you do not
smell gas, go to the next step.
1.
Turn off all electric power to the appliance if service is to be
performed (if applicable).
2.
Turn gas shut-off valve to
41921-0-0420
LIGHTING INSTRUCTIONS
to
TO TURN OFF GAS TO FIREPLACE
"OFF"
position.
WARNING
C. Use only the remote control or manual remote receiver
switch to operate the gas valve. Never use tools. If valve
does not operate, don't try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
6.
Turn ON electric power to the appliance.
7.
Find pilot - Follow metal tube from gas control. The pilot is
behind the burner on the right side.
8.
Turn main flame to on. If the pilot does not light within 60
"On"
seconds, stop and go to Step 5.
9.
If the burner or pilot does not operate properly after several
tries, turn the gas shut-off valve clockwise
"B"
"OFF"
and call your service technician or gas supplier.
10. Replace the front surround assembly or close bottom louver
assembly (if applicable).
11. Operation of the gas valve is controlled by a manual on/
off switch or a hand held remote control. Refer to remote
instructions for detailed operation information.
GAS SHUT-OFF VALVE
to
Page 23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvct30cbn95p-2Dvct35cbn95n-2Dvct35cbn95p-2Dvct30Dvct35

Table of Contents