Intermittent Pilot Lighting Instructions - Empire Comfort Systems MILLIVOLT DVCD FP3-4 Series Installation Instructions Manual

Direct-vent zero clearance gas fireplace heater
Table of Contents

Advertisement

INTERMITTENT PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
A.
This fireplace has a pilot which can be lighted with the
manual on/off switch, a remote control, or by switching the
receiver switch to the
follow these instructions exactly.
B.
BEFORE LIGHTING smell all around the fireplace area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical
switch. Do not use any phone in your building. Immediately
call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions. If you can not reach your gas
supplier, call the fire department.
1.
STOP! Read the safety information above.
2.
Turn OFF electric power to the fireplace.
3.
Open bottom louver if included, or remove the barrier
screen assembly.
4.
Turn gas valve counterclockwise
5.
Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow
in the safety information above on this page. If you do not
smell gas, go to the next step.
6.
Turn ON electric power to the fireplace.
7.
Find pilot - Follow metal tube from gas control. The pilot is
behind the burner on the right side.
8.
Turn main flame to on. If the pilot does not light within 60
seconds, stop and go to Step 5.
1.
Turn off all electric power to the fireplace if service is to be
performed (if applicable).
2.
Gain access to control compartment. Open bottom louver
assembly if included, or remove the barrier assembly.
38712-4-0920
"ON"
position. When lighting the pilot,
LIGHTING INSTRUCTIONS
to
"On"
TO TURN OFF GAS TO FIREPLACE
WARNING
C. Use only the remote control or manual remote receiver
switch to operate the gas valve. Never use tools. If valve
does not operate, don't try to repair it, call a qualified ser-
vice technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect the
fireplace and to replace any part of the control system and
any gas control which has been under water.
9.
Refer to remote control instructions for detailed information,
control features, and operation. NOTICE: There is a CPI/IPI
switch that allows for a continuous standing pilot mode or
an intermittent pilot mode. See fireplace manual for location
position.
of this switch. If the pilot or burner does not stay lit (in the
standing pilot mode), stop and immediately call a qualified
"B"
service technician or gas supplier.
10. If the burner or pilot does not operate properly after several
tries, turn the gas valve clockwise
call your service technician or gas supplier.
11. Replace the bottom louver assembly, or barrier screen
assembly.
12. Operation of the gas valve is controlled by a manual on/
off switch or a hand held remote control. Refer to remote
instructions for detailed operation information.
3.
Locate On/Off gas valve and turn clockwise to
"OFF". Do not force.
4.
Close bottom louver assembly if included, or replace the
barrier screen assembly.
GAS SHUT-OFF VALVE
to
"OFF"
and
Page 75