This appliance comes standard with a 120 VAC cord
assembly to accommodate the blower accessory. A junction
box may be installed in a bottom back corner of the existing
solid fuel masonry or factory built fireplace to connect the
cord assembly, or the supplied power cord may be routed
out onto the hearth to a nearby outlet.
A 120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.
Low voltage and 120 VAC cannot be shared within the same
wall box.
Once the appliance is installed check that the control
compartment wiring is secured so as to not interfere with the
blower, door latches, valve controls, or the barrier assembly.
Warranty Requirements
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown
on the rating plate is the responsibility of the person and
company making the change.
The warranty will be voided by, and the warranter disclaims any
responsibility for the following actions:
Installation of any damaged fireplace insert or vent system
component.
Modification of the fireplace insert or direct vent system.
Installation other than as instructed by Empire Comfort
Systems, Inc.
Improper positioning of the logs or glass door assembly.
Installation and/or use of any component part not
manufactured or approved by manufacturer.