Auto Setup - Panasonic PT-D1000 Specifications

Panasonic pt-d1000: user guide
Table of Contents

Advertisement

2. Basic Control Command
Explanatory notes
Yes: Enable
No: Disable
2.1.
Power ON (Lamp ON)
Hexadecimal
Character
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included)
Hexadecimal
Character
Acceptability
SECURITY
Yes
Notes:
• When you confirm whether to have succeeded in power-on, confirm it by QPW (query power condition) command after
receiving the callback of PON command.
• When REMOTE2 is effective, ER401 is returned as a response (callback).
2.2.
Power OFF (Standby)
Hexadecimal
Character
Response (Callback)
In the period when the command can be accepted (This command in power-off condition is included)
Hexadecimal
Character
Acceptability
SECURITY
Yes
Notes:
• When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after receiving
the callback of POF command.
• When REMOTE2 is effective, ER401 is returned as a response (callback).
2.3.

AUTO SETUP

Hexadecimal
Character
Response (Callback)
In the period when the command can be accepted
Hexadecimal
Character
Acceptability
SECURITY
No
Note:
• This command is acceptable only when RGB1 or RGB2 is selected and RGB PC signals are input. In other cases, ER401
is returned.
2.4.
SHUTTER
Hexadecimal
Character
Parameters (*1, *2)
Hexadecimal
Character
Response (Callback)
In the period when the command can be accepted
Hexadecimal
Character
Acceptability
SECURITY
Yes
Note:
• The setting by REMOTE2 is given to priority. When a command different from the setting of REMOTE2 is sent, ER402 is
returned.
02h
41h
A
02h
50h
P
STNDBY
NO SIGNAL
Yes
Yes
02h
41h
A
02h
50h
P
STNDBY
NO SIGNAL
Yes
Yes
02h
41h
A
02h
4Fh
O
STNDBY
NO SIGNAL
No
No
02h
41h
44h
A
D
Shutter OFF
30h
0
02h
4Fh
O
STNDBY
NO SIGNAL
No
Yes
44h
5Ah
5Ah
D
Z
Z
4Fh
4Eh
03h
O
N
SHUTTER
TEST PATTERN
Yes
Yes
44h
5Ah
5Ah
D
Z
Z
4Fh
46h
03h
O
F
SHUTTER
TEST PATTERN
Yes
Yes
44h
5Ah
5Ah
D
Z
Z
41h
53h
03h
A
S
SHUTTER
TEST PATTERN
No
No
5Ah
5Ah
3Bh
Z
Z
;
Shutter ON
31h
1
53h
48h
3Ah
S
H
:
SHUTTER
TEST PATTERN
Yes
Yes
4/62
3Bh
50h
4Fh
;
P
O
REMOTE2
(Yes)
3Bh
50h
4Fh
;
P
O
REMOTE2
(Yes)
3Bh
4Fh
41h
;
O
A
REMOTE2
Yes
4Fh
53h
48h
O
S
H
*1
03h
*2
REMOTE2
(Yes)
4Eh
03h
N
46h
03h
F
53h
03h
S
3Ah
*1
03h
:
*2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-dw10000Rs-232c