Using The Serial Terminals; Basic Format - Panasonic PT-D1000 Specifications

Panasonic pt-d1000: user guide
Table of Contents

Advertisement

Using the Serial Terminals

1. Basic Format

Transmission from the computer begins with STX, then the ID, command, parameter, and ETX are sent in this
order. Add parameters according to the details of control.
Basic control command (without parameter)
Start
ID
(STX)
1 byte
4 bytes
Basic control command (with parameters)
Start
ID
(STX)
1 byte
4 bytes
ID of the basic control command
ID
4 bytes
String
ALL
ADZZ
ID1
AD01
ID2
AD02
ID3
AD03
ID4
AD04
ID5
AD05
ID6
AD06
ID7
AD07
ID8
AD08
ID9
AD09
ID10
AD10
ID11
AD11
ID12
AD12
ID13
AD13
ID14
AD14
ID15
AD15
ID16
AD16
ID17
AD17
ID18
AD18
ID19
AD19
ID20
AD20
ID21
AD21
ID22
AD22
Separator
Command
(semicolon)
1 byte
3 bytes
Separator
Command
(semicolon)
1 byte
3 bytes
ID
4 bytes
String
ID23
AD23
ID24
AD24
ID25
AD25
ID26
AD26
ID27
AD27
ID28
AD28
ID29
AD29
ID30
AD30
ID31
AD31
ID32
AD32
ID33
AD33
ID34
AD34
ID35
AD35
ID36
AD36
ID37
AD37
ID38
AD38
ID39
AD39
ID40
AD40
ID41
AD41
ID42
AD42
ID43
AD43
ID44
AD44
ID45
AD45
End
(ETX)
1 byte
Separator
(colon)
1 byte
ID
4 bytes
String
ID46
AD46
ID47
AD47
ID48
AD48
ID49
AD49
ID50
AD50
ID51
AD51
ID52
AD52
ID53
AD53
ID54
AD54
ID55
AD55
ID56
AD56
ID57
AD57
ID58
AD58
ID59
AD59
ID60
AD60
ID61
AD61
ID62
AD62
ID63
AD63
ID64
AD64
Group A
AD0A
Group B
AD0B
Group C
AD0C
Group D
AD0D
2/62
Parameters
Undefined length
ID
4 bytes
String
Group E
AD0E
Group F
AD0F
Group-G
AD0G
Group H
AD0H
Group I
AD0I
Group J
AD0J
Group K
AD0K
Group L
AD0L
Group M
AD0M
Group N
AD0N
Group O
AD0O
Group P
AD0P
Group Q
AD0Q
Group R
AD0R
Group S
AD0S
Group T
AD0T
Group U
AD0U
Group V
AD0V
Group W
AD0W
Group X
AD0X
Group Y
AD0Y
Group Z
AD0Z
End
(ETX)
1 byte

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-dw10000Rs-232c

Table of Contents